{"public_id":"cl_07ad0160ad37ccc13ae378dfd259d150","status":"active","superseded_by_public_id":null,"corpus_id":6684687,"text":"Experimental results on datasets recorded from 12 subjects during fast running at 15 km/h showed an average absolute error of heart rate estimation of 2.34 beats per minute and a Pearson correlation of 0.992 between estimates and ground truth.","confidence":0.95,"paper":{"corpus_id":6684687,"title":"TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise","url":"https://sah.borca.ai/papers/6684687"},"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"origin_summary":{"object_type":"claim","status":"active","confidence":0.95,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":2,"verifier_classes":["system"],"verifier_class_counts":{"system":2,"user_agent":0},"verdict_counts":{"approve":1,"reject":1},"verifier_state":"system_only","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","claim.status","claim.confidence"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"concepts":[{"public_id":"co_1e0d743834eb10a83803e66caeb7b820","name":"average absolute error","description":"The mean absolute difference between estimated heart rate and ground truth, reported as 2.34 beats per minute.","types":["metric","performance measure"],"url":"https://sah.borca.ai/concepts/co_1e0d743834eb10a83803e66caeb7b820"},{"public_id":"co_6259137da013973a49083e4c7d2ebe2a","name":"Pearson correlation","description":"Correlation coefficient between estimated heart rate and ground truth, reported as 0.992.","types":["metric","performance measure"],"url":"https://sah.borca.ai/concepts/co_6259137da013973a49083e4c7d2ebe2a"},{"public_id":"co_cbe377d6e702fb6f78e870638dc602b4","name":"fast running at 15 km/h","description":"The peak speed of intensive exercise during which PPG signals were recorded for evaluation.","types":["experimental condition"],"url":"https://sah.borca.ai/concepts/co_cbe377d6e702fb6f78e870638dc602b4"},{"public_id":"co_f9aab41da0f1b3f0e022acf784bb4465","name":"12 subjects","description":"The number of participants from whom datasets were recorded during fast running at 15 km/h.","types":["study population"],"url":"https://sah.borca.ai/concepts/co_f9aab41da0f1b3f0e022acf784bb4465"}],"related_claims":[],"url":"https://sah.borca.ai/claims/cl_07ad0160ad37ccc13ae378dfd259d150"}