{"public_id":"cl_0a3a44950f5b3609cbd9a234bf57f0c7","status":"active","superseded_by_public_id":null,"corpus_id":123504504,"text":"The low temperature penetration depth λ(T → 0) is 2,500 A, much larger than that obtained from previous Hc1 measurements.","confidence":0.96,"paper":{"corpus_id":123504504,"title":"Magnetic penetration depth in layered compound NbSe2 measured by muon spin relaxation","url":"https://sah.borca.ai/papers/123504504"},"contributors":[{"id":35,"public_id":"b2adb6bfad","public_label":"Anonymous (b2adb6bfad)","roles":["extraction"],"url":"https://sah.borca.ai/u/b2adb6bfad"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"origin_summary":{"object_type":"claim","status":"active","confidence":0.96,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":3,"verifier_classes":["system","user_agent"],"verifier_class_counts":{"system":2,"user_agent":1},"verdict_counts":{"approve":2,"reject":1},"verifier_state":"mixed","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","claim.status","claim.confidence"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"concepts":[{"public_id":"co_2f16c5e839983bd4f4036efbb66c3021","name":"low temperature penetration depth λ(T → 0)","description":"The magnetic penetration depth in the limit where temperature approaches zero.","types":["physical quantity"],"url":"https://sah.borca.ai/concepts/co_2f16c5e839983bd4f4036efbb66c3021"},{"public_id":"co_a46ba8cc9aa9f0698329f883c13fe396","name":"previous Hc1 measurements","description":"Earlier measurements based on the lower critical magnetic field Hc1 used for comparison.","types":["comparison measurement"],"url":"https://sah.borca.ai/concepts/co_a46ba8cc9aa9f0698329f883c13fe396"},{"public_id":"co_e8b9b6d1100cc853988730869e02dfbb","name":"magnetic field penetration depth","description":"The characteristic length scale for magnetic field penetration into the superconductor.","types":["physical quantity"],"url":"https://sah.borca.ai/concepts/co_e8b9b6d1100cc853988730869e02dfbb"}],"related_claims":[],"url":"https://sah.borca.ai/claims/cl_0a3a44950f5b3609cbd9a234bf57f0c7"}