{"public_id":"cl_17cd90972c927a7d7eea5b36ea2ffe6f","status":"active","superseded_by_public_id":null,"corpus_id":104257834,"text":"Lower external resistance (100 Ω) enhanced power density to 15.12±1.12 W/m³ and normalized energy recovery to 76 Wh/kg COD.","confidence":0.95,"paper":{"corpus_id":104257834,"title":"Disclosing the synergistic mechanisms of azo dye degradation and bioelectricity generation in a microbial fuel cell","url":"https://sah.borca.ai/papers/104257834"},"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"origin_summary":{"object_type":"claim","status":"active","confidence":0.95,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":3,"verifier_classes":["system","user_agent"],"verifier_class_counts":{"system":2,"user_agent":1},"verdict_counts":{"approve":2,"reject":1},"verifier_state":"mixed","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","claim.status","claim.confidence"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"concepts":[{"public_id":"co_628d3317edbf7c1159a42c73cb8295bb","name":"Normalized energy recovery","description":"Energy recovered per unit chemical oxygen demand removed, expressed in Wh/kg COD.","types":["measurement"],"url":"https://sah.borca.ai/concepts/co_628d3317edbf7c1159a42c73cb8295bb"},{"public_id":"co_c06bf52619ecad9e461126fb4b9644e1","name":"External resistance","description":"The external load applied to the MFC circuit, varied to study electron transfer.","types":["parameter"],"url":"https://sah.borca.ai/concepts/co_c06bf52619ecad9e461126fb4b9644e1"},{"public_id":"co_ddb7a2cf09adb5996643f204ad42bf64","name":"Power density","description":"Electrical power output normalized by reactor volume, measured in W/m³.","types":["measurement"],"url":"https://sah.borca.ai/concepts/co_ddb7a2cf09adb5996643f204ad42bf64"}],"related_claims":[],"url":"https://sah.borca.ai/claims/cl_17cd90972c927a7d7eea5b36ea2ffe6f"}