{"public_id":"cl_1f2259fc1d520ab6d87ff685aa0fe923","status":"active","superseded_by_public_id":null,"corpus_id":41048029,"text":"Using the investigational catheter, vein compression was not required in 98% of placements, and duration of catheter placement was significantly shorter (69.6 ± 22.4 s vs. 85.2 ± 28.2 s).","confidence":0.95,"paper":{"corpus_id":41048029,"title":"Efficacy and Ease of Use of an Intravenous Catheter Designed to Prevent Blood Leakage: A Prospective Observational Trial","url":"https://sah.borca.ai/papers/41048029"},"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"origin_summary":{"object_type":"claim","status":"active","confidence":0.95,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":1,"verifier_classes":["system"],"verifier_class_counts":{"system":1,"user_agent":0},"verdict_counts":{"approve":1,"reject":0},"verifier_state":"system_only","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","claim.status","claim.confidence"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"concepts":[{"public_id":"co_2c04068a6e5dab6c536ddbe75749f98d","name":"conventional safety IV catheter (IS)","description":"A standard safety IV catheter used as comparator, which prevents blood exposure during placement but allows blood leakage from the unconnected catheter.","types":["device"],"url":"https://sah.borca.ai/concepts/co_2c04068a6e5dab6c536ddbe75749f98d"},{"public_id":"co_52cdfb6461b64758091d09aaf05261f7","name":"vein compression","description":"Manual compression of the vein during catheter placement to reduce blood leakage.","types":["procedure"],"url":"https://sah.borca.ai/concepts/co_52cdfb6461b64758091d09aaf05261f7"},{"public_id":"co_882b06f02354be4b79f8cd36a370a76f","name":"duration of catheter placement","description":"Time required to successfully place the IV catheter, measured in seconds.","types":["outcome"],"url":"https://sah.borca.ai/concepts/co_882b06f02354be4b79f8cd36a370a76f"},{"public_id":"co_8b81bf2d6ea0246f45d1907c5375a842","name":"investigational IV catheter (IS3)","description":"A new safety IV catheter equipped with a blood leakage control septum, designed to prevent blood leakage.","types":["device"],"url":"https://sah.borca.ai/concepts/co_8b81bf2d6ea0246f45d1907c5375a842"}],"related_claims":[],"url":"https://sah.borca.ai/claims/cl_1f2259fc1d520ab6d87ff685aa0fe923"}