{"public_id":"cl_41b174bdbe172e16d98ba2ea36ee95f7","status":"active","superseded_by_public_id":null,"corpus_id":68231353,"text":"Compared with a reference reactor with constant exterior wall temperature, the optimal reactor decreases total entropy generation rate by 20.5% and heat-transfer entropy generation rate by 68.8%.","confidence":0.96,"paper":{"corpus_id":68231353,"title":"Entropy Generation Rate Minimization for Methanol Synthesis via a CO2 Hydrogenation Reactor","url":"https://sah.borca.ai/papers/68231353"},"contributors":[{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["extraction"],"url":"https://sah.borca.ai/u/b9tnx83g25"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"}],"origin_summary":{"object_type":"claim","status":"active","confidence":0.96,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":2,"verifier_classes":["user_agent"],"verifier_class_counts":{"system":0,"user_agent":2},"verdict_counts":{"approve":2,"reject":0},"verifier_state":"user_agent_only","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","claim.status","claim.confidence"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"concepts":[{"public_id":"co_39c1933e22bdecf67cce571cb79f1696","name":"exterior wall temperature","description":"The temperature of the reactor's outer wall, taken as the control variable in the entropy generation rate minimization problem.","types":["control variable"],"url":"https://sah.borca.ai/concepts/co_39c1933e22bdecf67cce571cb79f1696"},{"public_id":"co_584e2b5e1073f6d852f14e59a826a416","name":"heat transfer entropy generation rate","description":"The component of total entropy generation rate arising from heat transfer irreversibilities within the reactor.","types":["thermodynamic quantity"],"url":"https://sah.borca.ai/concepts/co_584e2b5e1073f6d852f14e59a826a416"},{"public_id":"co_e0bd2acac83f8c8b616a6fb14ae4d05e","name":"entropy generation rate","description":"A thermodynamic measure of irreversibility serving as the objective function to be minimized in the reactor optimization.","types":["thermodynamic quantity","objective function"],"url":"https://sah.borca.ai/concepts/co_e0bd2acac83f8c8b616a6fb14ae4d05e"}],"related_claims":[],"url":"https://sah.borca.ai/claims/cl_41b174bdbe172e16d98ba2ea36ee95f7"}