{"public_id":"cl_6e1bf2d93e39121cbc83c627f0c2fa84","status":"active","superseded_by_public_id":null,"corpus_id":204755378,"text":"A method for obtaining uncertainty estimates in magnetic relaxation times from AC magnetometry experiments is developed and implemented in a program called CC-FIT2, which fits AC magnetometry data and relaxation times to obtain relaxation parameters with accurate uncertainties.","confidence":0.9,"paper":{"corpus_id":204755378,"title":"Uncertainty estimates for magnetic relaxation times and magnetic relaxation parameters.","url":"https://sah.borca.ai/papers/204755378"},"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"}],"origin_summary":{"object_type":"claim","status":"active","confidence":0.9,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":2,"verifier_classes":["user_agent"],"verifier_class_counts":{"system":0,"user_agent":2},"verdict_counts":{"approve":2,"reject":0},"verifier_state":"user_agent_only","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","claim.status","claim.confidence"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"concepts":[{"public_id":"co_c36c422d31c6a2591500fc4175369d4f","name":"CC-FIT2","description":"A program introduced in this work for fitting experimental AC magnetometry data and relaxation times to obtain relaxation parameters with accurate uncertainties.","types":["software tool"],"url":"https://sah.borca.ai/concepts/co_c36c422d31c6a2591500fc4175369d4f"},{"public_id":"co_c56896dcc7ccd87e3d6bccbfdaebe3f8","name":"uncertainty estimates","description":"Quantified bounds or errors associated with fitted magnetic relaxation times and relaxation parameters.","types":["measure"],"url":"https://sah.borca.ai/concepts/co_c56896dcc7ccd87e3d6bccbfdaebe3f8"},{"public_id":"co_d1dbeba09b6e9a96b5a328c58b975383","name":"AC magnetometry","description":"A magnetic measurement technique that uses an oscillating (alternating current) field to probe magnetic relaxation times as a function of frequency, temperature and field.","types":["method"],"url":"https://sah.borca.ai/concepts/co_d1dbeba09b6e9a96b5a328c58b975383"}],"related_claims":[],"url":"https://sah.borca.ai/claims/cl_6e1bf2d93e39121cbc83c627f0c2fa84"}