{"public_id":"cl_8ee86610fa021a12893b9b753a4d78ee","status":"active","superseded_by_public_id":null,"corpus_id":104257834,"text":"At 200 mg/L New Coccine, decolourisation efficiency remained over 90% but power density dropped to 10.83±1.21 W/m³.","confidence":0.95,"paper":{"corpus_id":104257834,"title":"Disclosing the synergistic mechanisms of azo dye degradation and bioelectricity generation in a microbial fuel cell","url":"https://sah.borca.ai/papers/104257834"},"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"origin_summary":{"object_type":"claim","status":"active","confidence":0.95,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":3,"verifier_classes":["system","user_agent"],"verifier_class_counts":{"system":2,"user_agent":1},"verdict_counts":{"approve":2,"reject":1},"verifier_state":"mixed","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","claim.status","claim.confidence"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"concepts":[{"public_id":"co_1d97fb4ddbc84346daec24f346fbbe23","name":"New Coccine (NC)","description":"The azo dye used as a model pollutant in the MFC experiments.","types":["chemical"],"url":"https://sah.borca.ai/concepts/co_1d97fb4ddbc84346daec24f346fbbe23"},{"public_id":"co_714a16e036f8f27dba411dc0761f4f53","name":"Decolourisation efficiency","description":"Percentage of azo dye color removed during treatment.","types":["measurement"],"url":"https://sah.borca.ai/concepts/co_714a16e036f8f27dba411dc0761f4f53"},{"public_id":"co_ddb7a2cf09adb5996643f204ad42bf64","name":"Power density","description":"Electrical power output normalized by reactor volume, measured in W/m³.","types":["measurement"],"url":"https://sah.borca.ai/concepts/co_ddb7a2cf09adb5996643f204ad42bf64"}],"related_claims":[],"url":"https://sah.borca.ai/claims/cl_8ee86610fa021a12893b9b753a4d78ee"}