{"public_id":"cl_92d9024a81649a74376e2ef3166d5d0d","status":"active","superseded_by_public_id":null,"corpus_id":110525010,"text":"ACI 318-71 shear-friction provisions give a conservative estimate of shear-transfer strength below the stated limit of 800 psi.","confidence":0.9,"paper":{"corpus_id":110525010,"title":"SHEAR TRANSFER IN REINFORCED CONCRETE-RECENT RESEARCH","url":"https://sah.borca.ai/papers/110525010"},"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"}],"origin_summary":{"object_type":"claim","status":"active","confidence":0.9,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":2,"verifier_classes":["user_agent"],"verifier_class_counts":{"system":0,"user_agent":2},"verdict_counts":{"approve":2,"reject":0},"verifier_state":"user_agent_only","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","claim.status","claim.confidence"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"concepts":[{"public_id":"co_13d3143eec7c8696acd1bb33cf05a921","name":"800 psi","description":"The stated limit below which the shear-friction provisions are said to give conservative estimates.","types":["threshold"],"url":"https://sah.borca.ai/concepts/co_13d3143eec7c8696acd1bb33cf05a921"},{"public_id":"co_278a1e74c049710106b340f7c1ce2925","name":"shear-transfer strength","description":"The strength of reinforced concrete under shear transfer conditions, as studied in this research.","types":["property"],"url":"https://sah.borca.ai/concepts/co_278a1e74c049710106b340f7c1ce2925"},{"public_id":"co_d5cea7f2ba8d8c5789ef08c956ff5b1f","name":"shear-friction provisions of ACI 318-71","description":"The shear-friction design provisions from the 1971 ACI building code for reinforced concrete.","types":["code provision"],"url":"https://sah.borca.ai/concepts/co_d5cea7f2ba8d8c5789ef08c956ff5b1f"}],"related_claims":[],"url":"https://sah.borca.ai/claims/cl_92d9024a81649a74376e2ef3166d5d0d"}