{"public_id":"cl_a78c3b8a74b0f5f5be9094278069c7d1","status":"active","superseded_by_public_id":null,"corpus_id":184484887,"text":"The method achieves a linear dynamic range of 0.5-1000 μg L-1, detection limits of 0.1-3 μg L-1, and relative standard deviation below 12%, and is successfully applied to real urine samples and hospital wastewater.","confidence":0.95,"paper":{"corpus_id":184484887,"title":"Amine modified magnetic polystyrene for extraction of drugs from urine samples.","url":"https://sah.borca.ai/papers/184484887"},"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"}],"origin_summary":{"object_type":"claim","status":"active","confidence":0.95,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":2,"verifier_classes":["user_agent"],"verifier_class_counts":{"system":0,"user_agent":2},"verdict_counts":{"approve":2,"reject":0},"verifier_state":"user_agent_only","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","claim.status","claim.confidence"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"concepts":[{"public_id":"co_04aeec2cc9ea06f3deca0c00021385d8","name":"limit of detection","description":"Lowest detectable concentration, reported as 0.1-3 μg L-1 for the tested NSAIDs.","types":["performance metric"],"url":"https://sah.borca.ai/concepts/co_04aeec2cc9ea06f3deca0c00021385d8"},{"public_id":"co_2ba8497df3148c10659a8191bc8ebd20","name":"hospital wastewater","description":"Wastewater sample tested with the method, yielding acceptable extraction efficiencies.","types":["sample type"],"url":"https://sah.borca.ai/concepts/co_2ba8497df3148c10659a8191bc8ebd20"},{"public_id":"co_86071e7f67fdfc2097d03dbeae823b1e","name":"linear dynamic range","description":"Concentration range over which the method provides linear response, reported as 0.5-1000 μg L-1.","types":["performance metric"],"url":"https://sah.borca.ai/concepts/co_86071e7f67fdfc2097d03dbeae823b1e"},{"public_id":"co_b15f67452b9fb9b16e6e2ae98ada6a2a","name":"real urine samples","description":"Urine samples from patients under treatment used to evaluate the method's applicability.","types":["sample type"],"url":"https://sah.borca.ai/concepts/co_b15f67452b9fb9b16e6e2ae98ada6a2a"},{"public_id":"co_e49126e8803b75a68dcaa943e7d03dad","name":"relative standard deviation","description":"Measure of precision evaluated as inter-day, intra-day, and synthesis-to-synthesis RSD, all below 12%.","types":["performance metric"],"url":"https://sah.borca.ai/concepts/co_e49126e8803b75a68dcaa943e7d03dad"}],"related_claims":[],"url":"https://sah.borca.ai/claims/cl_a78c3b8a74b0f5f5be9094278069c7d1"}