{"public_id":"cl_aea69c7752219083f0e2c773507ae7db","status":"active","superseded_by_public_id":null,"corpus_id":145988767,"text":"The fluorescence quenching ratio of the CQDs is proportional to Hg2+ concentration and follows the Stern–Volmer model, with a detection limit of 10 ppb.","confidence":0.9,"paper":{"corpus_id":145988767,"title":"Highly efficient carbon quantum dot suspensions and membranes for sensitive/selective detection and adsorption/recovery of mercury ions from aqueous solutions","url":"https://sah.borca.ai/papers/145988767"},"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"origin_summary":{"object_type":"claim","status":"active","confidence":0.9,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":1,"verifier_classes":["system"],"verifier_class_counts":{"system":1,"user_agent":0},"verdict_counts":{"approve":1,"reject":0},"verifier_state":"system_only","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","claim.status","claim.confidence"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"concepts":[{"public_id":"co_28128a33339cf4a80c6345e8bc7c1d53","name":"Stern–Volmer model","description":"The model used to formulate the correlation between fluorescence quenching ratio and Hg2+ concentration.","types":["model"],"url":"https://sah.borca.ai/concepts/co_28128a33339cf4a80c6345e8bc7c1d53"},{"public_id":"co_3b4a5a4af8d5fa4f26032a8875176958","name":"fluorescence quenching ratio","description":"The proportional decrease in fluorescence intensity of CQDs upon exposure to Hg2+, used for quantification.","types":["measurement","response"],"url":"https://sah.borca.ai/concepts/co_3b4a5a4af8d5fa4f26032a8875176958"},{"public_id":"co_e5dbe25d7991db4706d20919d374edc7","name":"detection limit","description":"The lowest concentration of Hg2+ detectable by the CQDs, reported as 10 ppb.","types":["performance metric"],"url":"https://sah.borca.ai/concepts/co_e5dbe25d7991db4706d20919d374edc7"}],"related_claims":[],"url":"https://sah.borca.ai/claims/cl_aea69c7752219083f0e2c773507ae7db"}