{"public_id":"co_0f7a9328397a84f7e8786a58d74a1619","status":"active","merged_into_public_id":null,"resolved_public_id":"co_0f7a9328397a84f7e8786a58d74a1619","name":"beam-to-column PTED connection","description":"A large-scale exterior beam-to-column specimen incorporating the PTED connection tested under cyclic loading.","aliases":[],"types":["experimental specimen"],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"origin_summary":{"object_type":"concept","status":"active","confidence":null,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":1,"verifier_classes":["system"],"verifier_class_counts":{"system":1,"user_agent":0},"verdict_counts":{"approve":1,"reject":0},"verifier_state":"system_only","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","concept.status"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"papers":[{"corpus_id":109770882,"title":"Posttensioned Energy Dissipating Connections for Moment-Resisting Steel Frames","citation_count":581,"url":"https://sah.borca.ai/papers/109770882"}],"claims":[{"public_id":"cl_18b9acdf951cc3d72acd7c856f94bcd8","text":"The analytical model and design procedure for PTED connections were validated against the experimental results.","corpus_id":109770882,"url":"https://sah.borca.ai/claims/cl_18b9acdf951cc3d72acd7c856f94bcd8"},{"public_id":"cl_23ceef69c8518af8c4762356403090b5","text":"A cyclic component test was performed on two energy dissipating bars and a cyclic test was conducted on a large-scale exterior beam-to-column PTED connection.","corpus_id":109770882,"url":"https://sah.borca.ai/claims/cl_23ceef69c8518af8c4762356403090b5"},{"public_id":"cl_62b8bb8934cd9e1446ea22579cff4c7d","text":"The PTED test specimen underwent large inelastic deformations without any damage to the beam or column and without residual drift.","corpus_id":109770882,"url":"https://sah.borca.ai/claims/cl_62b8bb8934cd9e1446ea22579cff4c7d"}],"related_concepts":[],"resolved_url":"https://sah.borca.ai/concepts/co_0f7a9328397a84f7e8786a58d74a1619","url":"https://sah.borca.ai/concepts/co_0f7a9328397a84f7e8786a58d74a1619"}