{"public_id":"co_18b213245ec655e2c24c3ea3a4d5c886","status":"active","merged_into_public_id":null,"resolved_public_id":"co_18b213245ec655e2c24c3ea3a4d5c886","name":"optimized ventilation","description":"The study arm in which ventilator settings were adjusted based on real-time analysis of flow and pressure waveforms.","aliases":[],"types":["intervention","method"],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"origin_summary":{"object_type":"concept","status":"active","confidence":null,"origin_kinds":["extraction","extraction_create"],"contribution_count":1,"contribution_task_types":["extraction"],"contribution_statuses":["applied"],"verifier_verdict_count":1,"verifier_classes":["system"],"verifier_class_counts":{"system":1,"user_agent":0},"verdict_counts":{"approve":1,"reject":0},"verifier_state":"system_only","basis":["kg_settlement_results.decision_payload.legacy_bridge","kg_entity_origin_refs","kg_assertion_proposals","contributions","verifications","concept.status"],"limits":["ledger provenance is aggregated; raw contribution and verifier audit rows are not expanded","entity matching uses settlement bridge refs and edge commands"]},"papers":[{"corpus_id":15285421,"title":"Optimization of ventilator setting by flow and pressure waveforms analysis during noninvasive ventilation for acute exacerbations of COPD: a multicentric randomized controlled trial","citation_count":54,"url":"https://sah.borca.ai/papers/15285421"}],"claims":[{"public_id":"cl_2e2d1af601b20e416b97380c22e06312","text":"Optimized ventilation guided by flow and pressure waveform analysis produced faster pH normalization at two hours than standard ventilation, normalizing pH in 51% versus 26% of patients.","corpus_id":15285421,"url":"https://sah.borca.ai/claims/cl_2e2d1af601b20e416b97380c22e06312"},{"public_id":"cl_374eb473b749f9f15adba2fc230c5b8f","text":"Optimized ventilation significantly improved patient's tolerance to ventilation at two hours compared with standard ventilation.","corpus_id":15285421,"url":"https://sah.borca.ai/claims/cl_374eb473b749f9f15adba2fc230c5b8f"},{"public_id":"cl_836472290b68f5d6e803fdc9fe314790","text":"Optimized ventilation led physicians to use higher levels of external positive end-expiratory pressure than standard ventilation.","corpus_id":15285421,"url":"https://sah.borca.ai/claims/cl_836472290b68f5d6e803fdc9fe314790"},{"public_id":"cl_8e3397b53f6686d6cb73ae20af13e3d2","text":"Optimized ventilation led physicians to select more sensitive inspiratory triggers and a faster speed of pressurization than standard ventilation.","corpus_id":15285421,"url":"https://sah.borca.ai/claims/cl_8e3397b53f6686d6cb73ae20af13e3d2"},{"public_id":"cl_ccab6e5c06d1129215688cb00268dc67","text":"Optimized ventilation produced a greater decrease in PaCO2 at two and six hours than standard ventilation.","corpus_id":15285421,"url":"https://sah.borca.ai/claims/cl_ccab6e5c06d1129215688cb00268dc67"}],"related_concepts":[],"resolved_url":"https://sah.borca.ai/concepts/co_18b213245ec655e2c24c3ea3a4d5c886","url":"https://sah.borca.ai/concepts/co_18b213245ec655e2c24c3ea3a4d5c886"}