A simple and accurate dosimetry protocol to estimate activity for hyperthyroidism treatment.

A. Skanjeti,A. Miranti,G. M. Delgado Yabar,Davide Bianciotto,E. Trevisiol,M. Stasi,V. Podio

Published 2015 in Nuclear medicine review. Central & Eastern Europe

ABSTRACT

BACKGROUND Aim of the study was to evaluate accuracy of different dosimetry protocols in estimating the required 131I activity to treat hyperthyroid patients. MATERIALS AND METHODS Forty consecutive patients were analysed: twenty-eight Graves' disease; twelve autonomous thyroid nodule (ATN). Maximum-uptake, effective half-time and residence-time were estimated from Radioiodine Uptake Test. Residence-time was estimated using a bi-compartmental model. For 131I activity calculation, algorithms laid down in European Association of Nuclear Medicine (EANM) guidelines, ICRP 53 approach and a mono-exponential formula (ME), were compared with OLINDA/EXM results. RESULTS Based on EANM guidelines, activities to be administered were 3% higher in Graves' disease (p = 0.001) and 3% higher in ATN (p = 0.046). Calculated activities using ICRP 53 approach were significantly lower compared to OLINDA/EXM: 33% in Graves' disease; 17% in ATN. Activities recommended by ME, were significantly higher: in Graves' disease 20%; 42% in ATN. CONCLUSIONS Only EANM algorithm predict quite well, compared to OLINDA/EXM, the required activity to treat hyperthyroid patients.

PUBLICATION RECORD

CITATION MAP

EXTRACTION MAP

CLAIMS

  • No claims are published for this paper.

CONCEPTS

  • No concepts are published for this paper.

REFERENCES

Showing 1-35 of 35 references · Page 1 of 1