Accurate and reproducible measurement of blood-brain barrier (BBB) integrity is critical in the assessment of the pathophysiology of the central nervous system disorders and in monitoring therapeutic effects. The widely-used low molecular weight marker [(14)C]sucrose is non-specific in the absence of chromatographic separation. The purpose of this study was to develop and validate a sensitive and reproducible LC-MS/MS method for the analysis of stable isotope-modified [(13)C12]sucrose in brain, plasma, and blood to determine BBB permeability to sucrose. After addition of internal standard (IS, [(13)C6]sucrose), the marker and IS were recovered from diluted rat blood, plasma, and brain homogenate by protein precipitation using acetonitrile. The recovery of the marker and IS was almost quantitative (90-106%) for all three matrices. The recovered samples were directly injected into an isocratic UPLC system with a run time of 6 min. Mass spectrometry was conducted using multiple reaction monitoring in negative mode. The method was linear (r(2)≥0.99) in the concentration ranges tested for the diluted blood and plasma (10-1000 ng/mL) and brain homogenate (1-200 ng/mL). The lower limit of quantitation of the assay was 0.5 pg injected on column. The assay was validated (n=5) based on acceptable intra- and inter-run accuracy and precision values. The method was successfully used for the measurement of serial blood and plasma and terminal brain concentrations of [(13)C12]sucrose after a single intravenous dose (10 mg/kg) of the marker to rats. As expected, the apparent brain uptake clearance values of [(13)C12]sucrose were low in healthy rats. The method may be useful for determination of the BBB integrity in animal models.
Development and validation of a sensitive UPLC-MS/MS method for the quantitation of [(13)C]sucrose in rat plasma, blood, and brain: Its application to the measurement of blood-brain barrier permeability.
M. K. Miah,U. Bickel,R. Mehvar
Published 2016 in Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
ABSTRACT
PUBLICATION RECORD
- Publication year
2016
- Venue
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
- Publication date
2016-03-15
- Fields of study
Medicine, Chemistry
- Identifiers
- External record
- Source metadata
Semantic Scholar, PubMed
CITATION MAP
EXTRACTION MAP
CLAIMS
- No claims are published for this paper.
CONCEPTS
- No concepts are published for this paper.
REFERENCES
Showing 1-30 of 30 references · Page 1 of 1
CITED BY
Showing 1-13 of 13 citing papers · Page 1 of 1