Purpose To investigate whether implantation of a glaucoma shunt device leads to inappropriate accumulation of plasma derived proteins in the aqueous humor. Methods Aqueous humor samples were collected from 11 patients (study group) with a glaucoma shunt device undergoing either cataract surgery or a corneal transplant and 11 patients (control) with senile cataract undergoing routine cataract extraction. Of the study group, 9 had an Ahmed valve implant and 2 eyes had a Baerveldt implant. Tryptic digests of the mixture of proteins in aqueous humor (AH) were analyzed using Liquid Chromatography/Mass Spectrometry (LC-MS/MS). Proteins were identified with high confidence using stringent criteria and compared quantitatively using a label-free platform (IdentiQuantXLTM). Results We identified 135 proteins in the albumin-depleted fraction in both the study and control group AH. Using stringent criteria, 13 proteins were detected at a significantly higher level compared to controls. These proteins are known to play a role in oxidative stress, apoptosis, inflammation and/or immunity and include gelsolin (p=0.00005), plasminogen (p=0.00009), angiotensinogen (p=0.0001), apolipoprotein A-II (p=0.0002), beta-2-microglobulin (p=0.0002), dickkopf-3 (DKK-3; p=0.0002), pigment epithelium-derived factor (p=0.0002), RIG-like 7–1 (p=0.0002), afamin (p=0.0003), fibronectin 1 (FN1; p=0.0003), apolipoprotein A-I (p=0.0004), activated complement C4 protein (C4a; p=0.0004) and prothrombin (p=0.0004). Many of the identified proteins were novel proteins that have not been associated with glaucoma in prior studies. All but C4a (complement C4 is a plasma protein but not in an activated form) are known plasma proteins and the elevated levels of these proteins in the aqueous humor suggests a breach in the blood-aqueous barrier with passive influx into the anterior chamber of the eye. Conclusions The presence of these proteins in the aqueous humor suggests that glaucoma shunt device causes either a breach in blood-aqueous barrier or chronic trauma, increasing influx of oxidative, apoptotic and inflammatory proteins that could potentially cause corneal endothelial damage.
Alterations in the aqueous humor proteome in patients with a glaucoma shunt device
A. Anshu,M. Price,M. Richardson,Zaneer M. Segu,Xianyin Lai,M. Yoder,F. Price
Published 2011 in Molecular Vision
ABSTRACT
PUBLICATION RECORD
- Publication year
2011
- Venue
Molecular Vision
- Publication date
2011-07-14
- Fields of study
Medicine
- Identifiers
- External record
- Source metadata
Semantic Scholar, PubMed
CITATION MAP
EXTRACTION MAP
CLAIMS
- No claims are published for this paper.
CONCEPTS
- No concepts are published for this paper.
REFERENCES
Showing 1-55 of 55 references · Page 1 of 1
CITED BY
Showing 1-94 of 94 citing papers · Page 1 of 1