{"corpus_id":107658176,"paper_sha":"1546cc053774801b1d7cd512ed0443d1d6fee5c1","doi":"10.1016/J.PROENG.2015.06.036","arxiv_id":null,"pmid":null,"pmcid":null,"mag_id":569496203,"dblp_id":null,"acl_id":null,"title":"Development of a Pressure Pulsation Damper for Gas Pressure Regulators with Account of Operation Parameters","year":2015,"publication_date":null,"venue":"","journal":{"name":"Procedia Engineering","pages":"277-283","volume":"106"},"journal_issn":null,"journal_title":null,"publication_types":[],"pubmed_pub_types":null,"s2_fields_of_study":["Engineering"],"reference_count":1,"citation_count":7,"influential_citation_count":0,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":1,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"Abstract A design concept of a gas flow pulsation damper at a pressure regulator outlet is offered. It is formulated the operational principle of this damper, which contains the orifice with high and low resistance and also the stabilizer (vortex damper) of an outflow. Future references for choosing the diameter and the amount of passages in the orifices are also done. It is proposed the sequence of choosing the damper parameters, which contains the stages of tentative gas-dynamic calculation of the plain washer parameters on basis of the Saint-Venant-Wenzel formula and the final modeling, produced on basis of the numerical simulation. It is presented the pulsation damper, which was developed by the offered method.","claims":[{"public_id":"cl_68a2ff8a97d06715f9581c2f3135c95a","status":"active","text":"A design concept for a gas flow pulsation damper at a pressure regulator outlet is proposed.","confidence":0.97,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_68a2ff8a97d06715f9581c2f3135c95a"},{"public_id":"cl_270d2ad5f4fd3c0a669cf0965e3d76f4","status":"active","text":"A parameter-selection sequence is proposed that uses tentative gas-dynamic calculation of plain washer parameters based on the Saint-Venant-Wenzel formula followed by final numerical simulation.","confidence":0.94,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_270d2ad5f4fd3c0a669cf0965e3d76f4"},{"public_id":"cl_6af233c81ab1f40a24c4aee475416ff8","status":"active","text":"Future references are provided for choosing the diameter and number of passages in the orifices.","confidence":0.9,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_6af233c81ab1f40a24c4aee475416ff8"},{"public_id":"cl_dfaf1747a12e780a1da29ebc6d39fef0","status":"active","text":"The damper's operational principle combines an orifice with high and low resistance and an outflow stabilizer in the form of a vortex damper.","confidence":0.95,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_dfaf1747a12e780a1da29ebc6d39fef0"}],"concepts":[{"public_id":"co_00ba1e2ab52fa536a6992f06fe4b2011","status":"active","name":"parameter-selection sequence","description":"An ordered procedure for choosing damper parameters from preliminary calculation to final modeling.","types":["method"],"aliases":["sequence of choosing the damper parameters"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_00ba1e2ab52fa536a6992f06fe4b2011"},{"public_id":"co_0c553fc978fb27165aa2a17ba06d04c9","status":"active","name":"orifice diameter","description":"The diameter of the orifice passages considered when selecting damper parameters.","types":["design parameter"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_0c553fc978fb27165aa2a17ba06d04c9"},{"public_id":"co_15500671f19b4f10ea71eb6717dc462c","status":"active","name":"orifice with high and low resistance","description":"An orifice-based flow element that provides both high- and low-resistance flow paths.","types":["component"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_15500671f19b4f10ea71eb6717dc462c"},{"public_id":"co_3299e17fb7f14921bde0a5f8a23de7c5","status":"active","name":"plain washer","description":"A washer whose parameters are estimated during the tentative gas-dynamic calculation stage.","types":["component"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_3299e17fb7f14921bde0a5f8a23de7c5"},{"public_id":"co_5503287378b02868a9762c0c4a9ebee6","status":"active","name":"gas flow pulsation damper","description":"A device designed to reduce pulsations in gas flow at a regulator outlet.","types":["device"],"aliases":["pulsation damper"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_5503287378b02868a9762c0c4a9ebee6"},{"public_id":"co_62b4cd57a47c6a6b337fc9e5e47c610d","status":"active","name":"numerical simulation","description":"Computational modeling used for the final stage of damper parameter refinement.","types":["method"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_62b4cd57a47c6a6b337fc9e5e47c610d"},{"public_id":"co_953e2929566f6bc50d71eb67ed764dbc","status":"active","name":"Saint-Venant-Wenzel formula","description":"A gas-dynamic formula used for tentative calculation of washer parameters.","types":["formula"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_953e2929566f6bc50d71eb67ed764dbc"},{"public_id":"co_d8f13c7430f33890ea690fbc6e4581d9","status":"active","name":"vortex damper","description":"A stabilizing device that uses vortex effects to smooth outflow.","types":["component"],"aliases":["stabilizer of an outflow"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_d8f13c7430f33890ea690fbc6e4581d9"},{"public_id":"co_dfcb405a79dc0acaa46882e3d3d3e17f","status":"active","name":"pressure regulator outlet","description":"The outlet side of a pressure regulator where the damper is installed.","types":["location"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_dfcb405a79dc0acaa46882e3d3d3e17f"},{"public_id":"co_ef3f7a65cd390af068b89e1fdcec406b","status":"active","name":"number of passages","description":"The count of passages in the orifice considered when selecting damper parameters.","types":["design parameter"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_ef3f7a65cd390af068b89e1fdcec406b"}],"external_ids":{"DOI":"10.1016/J.PROENG.2015.06.036","ArXiv":null,"PubMed":null,"PubMedCentral":null,"MAG":569496203,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/107658176","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":1},"paper_id":638357,"paper_uid":"7dcb1d2a-8eb7-4ec2-a230-28f7a41f532a","canonical_identity":{"paper_id":638357,"paper_uid":"7dcb1d2a-8eb7-4ec2-a230-28f7a41f532a","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/107658176"}