{"corpus_id":115284951,"paper_sha":"c698ab771a2dda711f946817a635224aa14d7f20","doi":"10.1016/J.MEASUREMENT.2018.05.039","arxiv_id":null,"pmid":null,"pmcid":null,"mag_id":2800218090,"dblp_id":null,"acl_id":null,"title":"Validity and reliability of the Balance Tracking System during feet together stance","year":2018,"publication_date":"2018-10-01","venue":"Measurement","journal":{"name":"Measurement","pages":null,"volume":null},"journal_issn":null,"journal_title":null,"publication_types":[],"pubmed_pub_types":null,"s2_fields_of_study":["Medicine","Computer Science","Engineering"],"reference_count":27,"citation_count":7,"influential_citation_count":0,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":1,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"Abstract Laboratory and clinical measures of postural control are commonly used in the diagnosis of concussion. A novel instrument, the Balance Tracking System (BTrackS), has similar instrumentation to a force platform (FP), with greater portability and reduced cost. The purpose was to evaluate the concurrent validity of derived center of pressure (CoP) excursion and mean velocity for the raw CoP coordinates produced by the BTrackS and FP during feet together quiet upright stance. Participants stood on the BTrackS and FP at two time points. The BTrackS excursion values were significantly lower than the FP values at both time points but the devices CoP excursion values were strongly related at both time points and in all conditions. For mean velocity data, there were no significant differences between the devices at any time point. The BTrackS had excellent test–retest reliability over time in all conditions for both the excursion and mean velocity data.","claims":[{"public_id":"cl_2b20170f7569f7159cb557f147d3c1e2","status":"active","text":"BTrackS center-of-pressure excursion values were significantly lower than force platform values at both time points, yet the two devices' excursion measures were strongly related across all conditions.","confidence":0.97,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_2b20170f7569f7159cb557f147d3c1e2"},{"public_id":"cl_e75d11e808aebf3361bbca91fad2d896","status":"active","text":"BTrackS mean velocity did not differ significantly from force platform mean velocity at any time point.","confidence":0.96,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_e75d11e808aebf3361bbca91fad2d896"},{"public_id":"cl_bc818851d749677027efbe863fdfa802","status":"active","text":"BTrackS showed excellent test-retest reliability over time for both center-of-pressure excursion and mean velocity across all conditions.","confidence":0.98,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_bc818851d749677027efbe863fdfa802"}],"concepts":[{"public_id":"co_13475c1c30ba38d9b684dc170e9890f5","status":"active","name":"concurrent validity","description":"The extent to which two measurement devices produce related results when used under the same conditions.","types":["measurement property"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_13475c1c30ba38d9b684dc170e9890f5"},{"public_id":"co_35e454c965a3d8cc6aea93e97491f2f6","status":"active","name":"mean velocity","description":"The average speed of center-of-pressure movement during quiet upright stance.","types":["measure"],"aliases":["CoP mean velocity"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_35e454c965a3d8cc6aea93e97491f2f6"},{"public_id":"co_44362dfca0a520f81f5e4cfe3dd79fd5","status":"active","name":"concussion","description":"A clinical condition for which laboratory and clinical measures of postural control are used in diagnosis.","types":["condition"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_44362dfca0a520f81f5e4cfe3dd79fd5"},{"public_id":"co_5c9051f118831a4fb68b01c73bc1aac6","status":"active","name":"force platform","description":"A reference postural control device used for comparison of center-of-pressure measures.","types":["device","measurement instrument"],"aliases":["FP"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_5c9051f118831a4fb68b01c73bc1aac6"},{"public_id":"co_a4f90f534242a3cbee7c1d43eb55b462","status":"active","name":"Balance Tracking System","description":"A novel portable postural control instrument used to measure raw center-of-pressure coordinates during quiet standing.","types":["device","measurement instrument"],"aliases":["BTrackS"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_a4f90f534242a3cbee7c1d43eb55b462"},{"public_id":"co_a693921787dc04236dfc6b3965084346","status":"active","name":"raw center of pressure coordinates","description":"Unprocessed coordinate data representing center-of-pressure location over time.","types":["data"],"aliases":["raw CoP coordinates"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_a693921787dc04236dfc6b3965084346"},{"public_id":"co_b5f42a271b804616804904eb71efb3f4","status":"active","name":"feet together quiet upright stance","description":"A standing posture with the feet together and the body upright and still.","types":["task","postural condition"],"aliases":["feet together stance","quiet upright stance"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_b5f42a271b804616804904eb71efb3f4"},{"public_id":"co_cf9cf0d5801abbc0eaf7fba731e2e45e","status":"active","name":"postural control","description":"The ability to maintain body position and balance during standing.","types":["physiological function"],"aliases":["balance control"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_cf9cf0d5801abbc0eaf7fba731e2e45e"},{"public_id":"co_d0b27816fc3576b93d15e623b7c03d25","status":"active","name":"test-retest reliability","description":"The consistency of repeated measurements taken across time points.","types":["measurement property"],"aliases":["reliability over time"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_d0b27816fc3576b93d15e623b7c03d25"},{"public_id":"co_e3f286d8d5c4605f93e6022bbe98c1eb","status":"active","name":"center of pressure excursion","description":"The amount of movement in the center of pressure during quiet upright stance.","types":["measure"],"aliases":["CoP excursion"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_e3f286d8d5c4605f93e6022bbe98c1eb"}],"external_ids":{"DOI":"10.1016/J.MEASUREMENT.2018.05.039","ArXiv":null,"PubMed":null,"PubMedCentral":null,"MAG":2800218090,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/115284951","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":1},"paper_id":636270,"paper_uid":"649d9cb0-462f-4ca9-b3e6-f5494e21ddff","canonical_identity":{"paper_id":636270,"paper_uid":"649d9cb0-462f-4ca9-b3e6-f5494e21ddff","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/115284951"}