{"corpus_id":116470364,"paper_sha":"535299acf24f11f13f29a46e4a1f8d3a363913e5","doi":"10.1016/J.APPLTHERMALENG.2018.12.016","arxiv_id":null,"pmid":null,"pmcid":null,"mag_id":2902053639,"dblp_id":null,"acl_id":null,"title":"Experimental study on the combustion characteristics of impinging diesel spray at low temperature environment","year":2019,"publication_date":"2019-02-01","venue":"Applied Thermal Engineering","journal":{"name":"Applied Thermal Engineering","pages":null,"volume":null},"journal_issn":null,"journal_title":null,"publication_types":[],"pubmed_pub_types":null,"s2_fields_of_study":["Materials Science","Engineering","Environmental Science"],"reference_count":34,"citation_count":35,"influential_citation_count":0,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":1,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"Abstract Impingement is a typical phenomenon occurring in diesel engine under cold start conditions. In this paper, the ignition and combustion characteristics of wall-impinging diesel spray under different wall conditions were investigated by using the high-speed photography, Mie scattering and Schlieren method on a constant volume chamber. It is found that the small wall distance and high wall temperature can accelerate the vaporization and mixing process of the spray, which shorten the ignition delay and accelerate the development of the flame. The wall angle has an obvious influence on the ignition position. The initial flame often appears first in the front of the downward spray. With the increase of wall angle, the promoting effect of the wall to the atomization and ignition is weakened, and the ignition delay increases. It is also found that the promotion of the wall on the combustion process mainly depends on the velocity component perpendicular to the wall. The research results of this paper will provide the basis of the control strategy for the cold start process of diesel engine.","claims":[{"public_id":"cl_027e5b3d44c6c20ac6846fd2b90e9298","status":"active","text":"Increasing wall angle weakens the promoting effect of the wall on atomization and ignition, increasing ignition delay.","confidence":0.9,"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_027e5b3d44c6c20ac6846fd2b90e9298"},{"public_id":"cl_458bf6eb2f243e5447c47b9ee11c1676","status":"active","text":"Small wall distance and high wall temperature accelerate vaporization and mixing of the spray, shortening ignition delay and accelerating flame development.","confidence":0.9,"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_458bf6eb2f243e5447c47b9ee11c1676"},{"public_id":"cl_fcd7f1eca348251b70677e6324524480","status":"active","text":"The promotion of the wall on the combustion process mainly depends on the velocity component perpendicular to the wall.","confidence":0.85,"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_fcd7f1eca348251b70677e6324524480"},{"public_id":"cl_365f69876aaaaea04116bdd8a8d327fc","status":"active","text":"The research results provide the basis of the control strategy for the cold start process of diesel engine.","confidence":0.8,"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_365f69876aaaaea04116bdd8a8d327fc"},{"public_id":"cl_2423e0bc2cdeacd0dfe63a0c3823dc2b","status":"active","text":"Wall angle influences ignition position; initial flame appears first in the front of the downward spray.","confidence":0.9,"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_2423e0bc2cdeacd0dfe63a0c3823dc2b"}],"concepts":[{"public_id":"co_0cc1d0ba1f7c6b0f32ef83bb7f0eb3f1","status":"active","name":"vaporization and mixing process","description":"The combined processes of fuel evaporation and mixing with air.","types":["process"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_0cc1d0ba1f7c6b0f32ef83bb7f0eb3f1"},{"public_id":"co_2808cbcd5a6ee6da06a2c172f40cb3a4","status":"active","name":"wall angle","description":"The angle of the wall relative to the spray direction.","types":["parameter"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_2808cbcd5a6ee6da06a2c172f40cb3a4"},{"public_id":"co_3c13a349b8353b1a89dbf1fc73480edd","status":"active","name":"cold start process","description":"The engine startup under low temperature conditions.","types":["condition"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_3c13a349b8353b1a89dbf1fc73480edd"},{"public_id":"co_49d9b0f5800e9b41518b0bc7de324acc","status":"active","name":"wall temperature","description":"The temperature of the wall surface.","types":["parameter"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_49d9b0f5800e9b41518b0bc7de324acc"},{"public_id":"co_57d3b37cf09e68816950d3d290afe03e","status":"active","name":"flame development","description":"The propagation and growth of the flame after ignition.","types":["phenomenon"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_57d3b37cf09e68816950d3d290afe03e"},{"public_id":"co_5a9c2e1b49b7c3efdd5324cef1ffa0c7","status":"active","name":"combustion process","description":"The overall combustion of the diesel spray.","types":["phenomenon"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_5a9c2e1b49b7c3efdd5324cef1ffa0c7"},{"public_id":"co_63e3b4d9862cab2b6fbe984595506011","status":"active","name":"ignition delay","description":"The time interval from fuel injection to ignition.","types":["measurement"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_63e3b4d9862cab2b6fbe984595506011"},{"public_id":"co_83f3c9a632cfb2d1d89cbf22f39a085d","status":"active","name":"ignition position","description":"The location where the initial flame appears.","types":["phenomenon"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_83f3c9a632cfb2d1d89cbf22f39a085d"},{"public_id":"co_914c304f2985f057319d4085c6cfe0c8","status":"active","name":"atomization","description":"The breakup of the liquid spray into fine droplets.","types":["process"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_914c304f2985f057319d4085c6cfe0c8"},{"public_id":"co_98486db3d61f259685e3defc7a9c243b","status":"active","name":"velocity component perpendicular to the wall","description":"The component of spray velocity that is normal to the wall surface.","types":["parameter"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_98486db3d61f259685e3defc7a9c243b"},{"public_id":"co_b03d85946b15c9e87c8813f6e8292f44","status":"active","name":"control strategy","description":"The engine management approach for cold start.","types":["method"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_b03d85946b15c9e87c8813f6e8292f44"},{"public_id":"co_dd0d72984fdf83fffe7804d7b5c8d4bf","status":"active","name":"downward spray","description":"The spray portion moving downward after impingement on the wall.","types":["phenomenon"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_dd0d72984fdf83fffe7804d7b5c8d4bf"},{"public_id":"co_e31ee1543427bc982288428b67ece0d3","status":"active","name":"wall distance","description":"The distance between the wall and the spray injection point.","types":["parameter"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_e31ee1543427bc982288428b67ece0d3"},{"public_id":"co_f434371d8dd5bb0565b45cc8537f7262","status":"active","name":"diesel engine","description":"The internal combustion engine using diesel fuel.","types":["system"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_f434371d8dd5bb0565b45cc8537f7262"},{"public_id":"co_f926aa65ba06bed3965839dd557c8e4d","status":"active","name":"promoting effect","description":"The beneficial influence of the wall on spray atomization and ignition.","types":["effect"],"aliases":[],"contributors":[{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["extraction"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":2,"public_id":"4715169a40","public_label":"AK (4715169a40)","roles":["review"],"url":"https://sah.borca.ai/u/4715169a40"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_f926aa65ba06bed3965839dd557c8e4d"}],"external_ids":{"DOI":"10.1016/J.APPLTHERMALENG.2018.12.016","ArXiv":null,"PubMed":null,"PubMedCentral":null,"MAG":2902053639,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/116470364","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":1},"paper_id":631542,"paper_uid":"e0b77ac2-61b6-4d63-b316-23fccbe50589","canonical_identity":{"paper_id":631542,"paper_uid":"e0b77ac2-61b6-4d63-b316-23fccbe50589","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/116470364"}