{"corpus_id":15703616,"paper_sha":"12265fb906d4d6b7e2762231ab5a186a64fa1d81","doi":"10.1364/OE.11.000889","arxiv_id":null,"pmid":19461802,"pmcid":null,"mag_id":2007795523,"dblp_id":null,"acl_id":null,"title":"Performance of fourier domain vs. time domain optical coherence tomography.","year":2003,"publication_date":"2003-04-21","venue":"Optics Express","journal":{"name":"Optics express","pages":"\n          889-94\n        ","volume":"11 8"},"journal_issn":null,"journal_title":null,"publication_types":["JournalArticle"],"pubmed_pub_types":["Journal Article"],"s2_fields_of_study":["Medicine","Physics","Engineering"],"reference_count":9,"citation_count":2013,"influential_citation_count":54,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":5,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"In this article we present a detailed discussion of noise sources in Fourier Domain Optical Coherence Tomography (FDOCT) setups. The performance of FDOCT with charge coupled device (CCD) cameras is compared to current standard time domain OCT systems. We describe how to measure sensitivity in the case of FDOCT and confirm the theoretically obtained values. It is shown that FDOCT systems have a large sensitivity advantage and allow for sensitivities well above 80dB, even in situations with low light levels and high speed detection.","claims":[{"public_id":"cl_79a87df11119a20bc4e41d8490c60a59","status":"active","text":"A sensitivity measurement approach for Fourier domain optical coherence tomography is described and the measured values match the theoretically obtained values.","confidence":0.94,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_79a87df11119a20bc4e41d8490c60a59"},{"public_id":"cl_0a8c8eca2fdb24667660a410e16bada7","status":"active","text":"Fourier domain optical coherence tomography can achieve sensitivities well above 80 dB even under low light levels and high-speed detection.","confidence":0.97,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_0a8c8eca2fdb24667660a410e16bada7"},{"public_id":"cl_622da12d43a71b9fb7975d8e40cfb431","status":"active","text":"Fourier domain optical coherence tomography with charge-coupled device cameras has a large sensitivity advantage over current standard time-domain optical coherence tomography systems.","confidence":0.98,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_622da12d43a71b9fb7975d8e40cfb431"}],"concepts":[{"public_id":"co_011b3c1f8f7def83d8caf691d7bdcc44","status":"active","name":"sensitivity measurement","description":"The procedure used to quantify detection sensitivity in the Fourier domain optical coherence tomography setup.","types":["measurement method"],"aliases":["measure sensitivity"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_011b3c1f8f7def83d8caf691d7bdcc44"},{"public_id":"co_423516d69dd8cd23603d0e2c84970b88","status":"active","name":"theoretically obtained values","description":"The predicted sensitivity values derived from theoretical analysis of the Fourier domain optical coherence tomography setup.","types":["theoretical result"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_423516d69dd8cd23603d0e2c84970b88"},{"public_id":"co_70841878e01786b5e833cb14657c0b9b","status":"active","name":"Fourier Domain Optical Coherence Tomography","description":"An optical coherence tomography approach that acquires depth information in the Fourier domain.","types":["imaging method"],"aliases":["FDOCT"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_70841878e01786b5e833cb14657c0b9b"},{"public_id":"co_83f432dd44ded86cc69ecd6c7a1ad9ee","status":"active","name":"charge coupled device cameras","description":"Detector cameras used in Fourier domain optical coherence tomography setups to record spectral data.","types":["detector"],"aliases":["CCD cameras","CCD"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_83f432dd44ded86cc69ecd6c7a1ad9ee"},{"public_id":"co_90387abed6224178a3a5f504f4f75f35","status":"active","name":"sensitivity","description":"The ability of an optical coherence tomography system to detect weak signals.","types":["performance metric"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_90387abed6224178a3a5f504f4f75f35"},{"public_id":"co_9b8ed68741d2b8688fc48d2831f1ced6","status":"active","name":"low light levels","description":"Operating conditions in which the detected optical signal intensity is very small.","types":["operating condition"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_9b8ed68741d2b8688fc48d2831f1ced6"},{"public_id":"co_bc71eca8259b7e3522ebd95792de90d0","status":"active","name":"high-speed detection","description":"Fast data acquisition or signal detection in the imaging system.","types":["operating condition"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_bc71eca8259b7e3522ebd95792de90d0"},{"public_id":"co_df881355939560e37b29d4feabaab61f","status":"active","name":"time domain OCT systems","description":"Optical coherence tomography systems that obtain depth information by scanning in the time domain.","types":["imaging system"],"aliases":["time domain optical coherence tomography","TD-OCT"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_df881355939560e37b29d4feabaab61f"}],"external_ids":{"DOI":"10.1364/OE.11.000889","ArXiv":null,"PubMed":19461802,"PubMedCentral":null,"MAG":2007795523,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/15703616","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":5},"paper_id":631537,"paper_uid":"18a89cd1-0536-4bdb-9572-9d3a423b06dd","canonical_identity":{"paper_id":631537,"paper_uid":"18a89cd1-0536-4bdb-9572-9d3a423b06dd","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/15703616"}