{"corpus_id":17303352,"paper_sha":"15841ac0b5f8a4f4859ae9489fc9de2e46190779","doi":"10.1186/ar2701","arxiv_id":null,"pmid":19454011,"pmcid":"2714118","mag_id":2146294830,"dblp_id":null,"acl_id":null,"title":"Magnetically retainable microparticles for drug delivery to the joint: efficacy studies in an antigen-induced arthritis model in mice","year":2009,"publication_date":"2009-05-19","venue":"Arthritis Research & Therapy","journal":{"name":"Arthritis Research & Therapy","pages":"R72 - R72","volume":"11"},"journal_issn":null,"journal_title":null,"publication_types":["JournalArticle","Study"],"pubmed_pub_types":["Comparative Study","Journal Article"],"s2_fields_of_study":["Medicine","Chemistry"],"reference_count":22,"citation_count":46,"influential_citation_count":1,"is_open_access":true,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":[{"d":"Animals","mj":false,"ui":"D000818"},{"d":"Arthritis, Experimental","mj":false,"qs":[{"q":"chemically induced","mj":false,"ui":"Q000139"},{"q":"drug therapy","mj":false,"ui":"Q000188"},{"q":"metabolism","mj":true,"ui":"Q000378"}],"ui":"D001169"},{"d":"Capsules","mj":false,"ui":"D002214"},{"d":"Dexamethasone","mj":false,"qs":[{"q":"administration & dosage","mj":false,"ui":"Q000008"},{"q":"pharmacokinetics","mj":false,"ui":"Q000493"}],"ui":"D003907"},{"d":"Disease Models, Animal","mj":true,"ui":"D004195"},{"d":"Drug Delivery Systems","mj":false,"qs":[{"q":"methods","mj":true,"ui":"Q000379"}],"ui":"D016503"},{"d":"Freund's Adjuvant","mj":false,"qs":[{"q":"toxicity","mj":false,"ui":"Q000633"}],"ui":"D005620"},{"d":"Knee Joint","mj":false,"qs":[{"q":"drug effects","mj":false,"ui":"Q000187"},{"q":"metabolism","mj":true,"ui":"Q000378"},{"q":"pathology","mj":false,"ui":"Q000473"}],"ui":"D007719"},{"d":"Magnetics","mj":true,"ui":"D008280"},{"d":"Male","mj":false,"ui":"D008297"},{"d":"Mice","mj":false,"ui":"D051379"},{"d":"Mice, Inbred C57BL","mj":false,"ui":"D008810"}],"chemicals":[{"n":"Capsules","ui":"D002214","reg":"0"},{"n":"Dexamethasone","ui":"D003907","reg":"7S5I7G3JQL"},{"n":"Freund's Adjuvant","ui":"D005620","reg":"9007-81-2"}],"comments_corrections":null,"source_flags":5,"s2_open_access_pdf_url":"https://arthritis-research.biomedcentral.com/counter/pdf/10.1186/ar2701","s2_open_access_landing_url":"https://www.semanticscholar.org/paper/15841ac0b5f8a4f4859ae9489fc9de2e46190779","s2_open_access_license":"CCBY","s2_open_access_status":"GOLD","pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"IntroductionConventional corticosteroid suspensions for the intra-articular treatment of arthritis suffer from limitations such as crystal formation or rapid clearance from the joint. The purpose of this study was to investigate an innovative alternative consisting of corticosteroid encapsulation into magnetically retainable microparticles.MethodsMicroparticles (1 or 10 μm) containing both superparamagnetic iron oxide nanoparticles (SPIONs) and dexamethasone 21-acetate (DXM) were prepared. In a preliminary study, we compared the persistence of microparticles of both sizes in the joint. A second study evaluated the influence of a subcutaneously implanted magnet near the knee on the retention of magnetic microparticles in the joint by in vivo imaging. Finally, the efficacy of 10-μm microparticles was investigated using a model of antigen-induced arthritis (AIA) in mice. Phosphate-buffered saline, DXM suspension, SPION suspension, blank microparticles and microparticles containing only SPIONs were used as controls. Arthritis severity was assessed using 99mTc accumulation and histological scoring.ResultsDue to their capacity of encapsulating more corticosteroid and their increased joint retention, the 10-μm microparticles were more suitable vectors than the 1-μm microparticles for corticosteroid delivery to the joint. The presence of a magnet resulted in higher magnetic retention in the joint, as demonstrated by a higher fluorescence signal. The therapeutic efficacy in AIA of 10-μm microparticles containing DXM and SPIONs was similar to that of the DXM suspension, proving that the bioactive agent is released. Moreover, the anti-inflammatory effect of DXM-containing microparticles was more important than that of blank microparticles or microparticles containing only SPIONs. The presence of a magnet did not induce a greater inflammatory reaction.ConclusionsThis study confirms the effectiveness of an innovative approach of using magnetically retainable microparticles as intra-articular drug delivery systems. A major advantage comes from a versatile polymer matrix, which allows the encapsulation of many classes of therapeutic agents (for example, p38 mitogen-activated protein kinase inhibitors), which may reduce systemic side effects.","claims":[{"public_id":"cl_d78bb98ce0dc6345f6cb77223e9c3ab5","status":"active","text":"10-μm microparticles encapsulating both superparamagnetic iron oxide nanoparticles and dexamethasone 21-acetate were more suitable vectors than 1-μm microparticles for corticosteroid delivery to the joint due to higher encapsulation capacity and increased joint retention.","confidence":0.95,"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_d78bb98ce0dc6345f6cb77223e9c3ab5"},{"public_id":"cl_25bded624b9be83ef80d8ff322ec3991","status":"active","text":"The anti-inflammatory effect of dexamethasone 21-acetate-containing microparticles was more important than that of blank microparticles or microparticles containing only superparamagnetic iron oxide nanoparticles.","confidence":0.9,"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_25bded624b9be83ef80d8ff322ec3991"},{"public_id":"cl_990b0f85b3495320d8f573ae3af565ec","status":"active","text":"The presence of a magnet did not induce a greater inflammatory reaction in the antigen-induced arthritis model.","confidence":0.85,"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_990b0f85b3495320d8f573ae3af565ec"},{"public_id":"cl_7d2d7d9b7097efd00d40e4e8b363be3c","status":"active","text":"The presence of a subcutaneously implanted magnet near the knee resulted in higher magnetic retention of magnetic microparticles in the joint, as demonstrated by a higher fluorescence signal.","confidence":0.9,"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_7d2d7d9b7097efd00d40e4e8b363be3c"},{"public_id":"cl_82e5bb10ed8a6eed99cbf61036e5c625","status":"active","text":"The therapeutic efficacy in antigen-induced arthritis of 10-μm microparticles containing dexamethasone 21-acetate and superparamagnetic iron oxide nanoparticles was similar to that of the dexamethasone 21-acetate suspension, indicating release of the bioactive agent.","confidence":0.9,"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_82e5bb10ed8a6eed99cbf61036e5c625"}],"concepts":[{"public_id":"co_0b6ed50e26f6bbe0400f2f8492e3168a","status":"active","name":"inflammatory reaction","description":"The degree of inflammation induced by the presence of the magnet in the arthritis model.","types":["outcome","phenomenon"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_0b6ed50e26f6bbe0400f2f8492e3168a"},{"public_id":"co_226e872059172167ad0bdb6ef819d1f7","status":"active","name":"fluorescence signal","description":"Signal from in vivo imaging used to measure the retention of magnetic microparticles in the joint.","types":["measurement","imaging modality"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_226e872059172167ad0bdb6ef819d1f7"},{"public_id":"co_261a052012d39580ae8f8dc94dc35dfe","status":"active","name":"joint retention","description":"Persistence of microparticles within the joint after intra-articular injection.","types":["property","outcome"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_261a052012d39580ae8f8dc94dc35dfe"},{"public_id":"co_2d3ab772ce50cb729994c0f211ee18e6","status":"active","name":"magnetic retention","description":"Enhanced retention of magnetic microparticles in the joint due to an external magnetic field.","types":["phenomenon","mechanism"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_2d3ab772ce50cb729994c0f211ee18e6"},{"public_id":"co_376a134a6fe09d8e9419729d0a5a65be","status":"active","name":"subcutaneously implanted magnet","description":"A magnet placed under the skin near the knee to enhance magnetic retention of microparticles in the joint.","types":["device","intervention"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_376a134a6fe09d8e9419729d0a5a65be"},{"public_id":"co_58739d06da92cc40f8dc89f7abb028f9","status":"active","name":"superparamagnetic iron oxide nanoparticles","description":"Superparamagnetic iron oxide nanoparticles (SPIONs) encapsulated in microparticles for magnetic retention.","types":["nanoparticle","imaging agent"],"aliases":["SPIONs"],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_58739d06da92cc40f8dc89f7abb028f9"},{"public_id":"co_7ae677319222d19c28fbe12f435a68f1","status":"active","name":"antigen-induced arthritis","description":"A mouse model of arthritis used to evaluate the therapeutic efficacy of microparticle formulations.","types":["disease model","experimental model"],"aliases":["AIA"],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_7ae677319222d19c28fbe12f435a68f1"},{"public_id":"co_9da1ba70e71dcb3c0d5c7e9e131c16c6","status":"active","name":"magnet","description":"An external magnet used to enhance retention of magnetic microparticles; assessed for inflammatory reaction.","types":["device","intervention"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_9da1ba70e71dcb3c0d5c7e9e131c16c6"},{"public_id":"co_a61c898fb311f02d90292441e3ad0e62","status":"active","name":"blank microparticles","description":"Microparticles without any drug or SPIONs used as a control.","types":["control","material"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_a61c898fb311f02d90292441e3ad0e62"},{"public_id":"co_cd2f32b65d39275b3c30e03fe616e89a","status":"active","name":"10-μm microparticles","description":"Microparticles of 10 μm diameter used as vectors for drug delivery to the joint.","types":["material","drug delivery system"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_cd2f32b65d39275b3c30e03fe616e89a"},{"public_id":"co_dcf2a759fcca9f1e140e58f88c6b0b43","status":"active","name":"microparticles containing only superparamagnetic iron oxide nanoparticles","description":"Microparticles containing SPIONs but no dexamethasone 21-acetate, used as a control.","types":["control","material"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_dcf2a759fcca9f1e140e58f88c6b0b43"},{"public_id":"co_f0d96d841942ebc6214f1815c7e1199b","status":"active","name":"dexamethasone 21-acetate","description":"A corticosteroid (DXM) encapsulated in microparticles for intra-articular treatment.","types":["drug","therapeutic agent"],"aliases":["DXM"],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_f0d96d841942ebc6214f1815c7e1199b"}],"external_ids":{"DOI":"10.1186/ar2701","ArXiv":null,"PubMed":19454011,"PubMedCentral":"2714118","MAG":2146294830,"DBLP":null,"ACL":null},"open_access":{"is_open_access":true,"pdf_url":"https://arthritis-research.biomedcentral.com/counter/pdf/10.1186/ar2701","landing_url":"https://www.semanticscholar.org/paper/15841ac0b5f8a4f4859ae9489fc9de2e46190779","source":"semantic_scholar","pdf_url_source":"semantic_scholar_open_access_pdf","license":"CCBY","status":"GOLD","reason":null},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":5},"paper_id":634144,"paper_uid":"66023eea-bf1a-45a3-a716-0cc41be8c91c","canonical_identity":{"paper_id":634144,"paper_uid":"66023eea-bf1a-45a3-a716-0cc41be8c91c","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/17303352"}