{"corpus_id":182620577,"paper_sha":"f54936689b6f33d0541ed623298a18c65984d040","doi":"10.1109/JSEN.2019.2917617","arxiv_id":null,"pmid":null,"pmcid":null,"mag_id":2944928173,"dblp_id":null,"acl_id":null,"title":"Smart Textile Based on Piezoresistive Sensing Elements for Respiratory Monitoring","year":2019,"publication_date":"2019-09-01","venue":"IEEE Sensors Journal","journal":{"name":"IEEE Sensors Journal","pages":"7718-7725","volume":"19"},"journal_issn":null,"journal_title":null,"publication_types":[],"pubmed_pub_types":null,"s2_fields_of_study":["Medicine","Materials Science","Computer Science","Engineering"],"reference_count":34,"citation_count":69,"influential_citation_count":2,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":1,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"Wearable systems are gaining large interest in applications related to the monitoring of physiological parameters. Piezoresistive strain sensors are a valid option to develop wearables for several medical applications. Among them, respiratory monitoring can be performed by recording chest movements. The aim of this paper is threefold: 1) the experimental assessment of elastic piezoresistive textile; 2) the influence of length and width on piezoresistive response; and 3) the use of these elements to develop a smart textile (ST) for respiratory monitoring. The ST consists of six piezoresistive elements. The static calibration and the hysteresis analysis were carried out to assess the characteristics of the piezoresistive elements. The feasibility assessment of the ST for respiratory monitoring was performed on four healthy volunteers under two conditions (i.e., quiet breathing and tachypnea). Respiratory frequency values were estimated by the ST and compared with the ones gathered by means of a reference system (i.e., a motion capture system). Length and width influence both the sensitivity and hysteresis of the piezoresistive element. Regarding the ST performance, good agreement with data provided by the reference system was found. Indeed, results obtained by considering the output of single sensing elements and their sum were promising: the difference between the average respiratory frequency was always lower than 1% and 4% during quiet breathing and tachypnea, respectively. The proposed ST seems to be suitable for respiratory frequency monitoring in a wide range of values, where unobtrusiveness is of great value.","claims":[{"public_id":"cl_930ac8c101f63ab8bc4c6d3ed2f800bb","status":"active","text":"A smart textile consisting of six piezoresistive elements was developed for respiratory monitoring.","confidence":0.94,"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_930ac8c101f63ab8bc4c6d3ed2f800bb"},{"public_id":"cl_6078ad80cfe52d11f72bf697f23c0f6b","status":"active","text":"Elastic piezoresistive textile was experimentally assessed as sensing material for wearable respiratory monitoring.","confidence":0.9,"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_6078ad80cfe52d11f72bf697f23c0f6b"},{"public_id":"cl_50b587dc13f5b269c9ba0b1007f7fc8e","status":"active","text":"Length and width influence both the sensitivity and hysteresis of the piezoresistive element.","confidence":0.97,"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_50b587dc13f5b269c9ba0b1007f7fc8e"},{"public_id":"cl_57e0e1c5d91efb6286d54fc9940738e7","status":"active","text":"Respiratory frequency estimated by the smart textile showed good agreement with a motion capture reference system in four healthy volunteers during quiet breathing and tachypnea.","confidence":0.95,"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_57e0e1c5d91efb6286d54fc9940738e7"},{"public_id":"cl_2cf9893735f04fc0e3536831270851ce","status":"active","text":"The difference between average respiratory frequency from the smart textile and the reference system was always lower than 1% during quiet breathing and 4% during tachypnea.","confidence":0.97,"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_2cf9893735f04fc0e3536831270851ce"}],"concepts":[{"public_id":"co_1998cdd732ad0cc4af8c687dd96c8618","status":"active","name":"smart textile","description":"A textile-based wearable system developed in the paper for monitoring respiratory movement.","types":["system"],"aliases":["ST"],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_1998cdd732ad0cc4af8c687dd96c8618"},{"public_id":"co_1a67904951fe88adb21105c66e48d63b","status":"active","name":"hysteresis","description":"A sensing characteristic describing path-dependent differences in piezoresistive response during loading and unloading.","types":["performance measure"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_1a67904951fe88adb21105c66e48d63b"},{"public_id":"co_42c3fcd580076840c47ab49abc2ae144","status":"active","name":"four healthy volunteers","description":"The human participant group used to assess feasibility of the smart textile for respiratory monitoring.","types":["study population"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_42c3fcd580076840c47ab49abc2ae144"},{"public_id":"co_5f8631e74c62221a403a6daaef473ebb","status":"active","name":"quiet breathing","description":"A normal breathing condition used during feasibility testing of the smart textile.","types":["experimental condition"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_5f8631e74c62221a403a6daaef473ebb"},{"public_id":"co_7793a3d66a265acce4789ecd16cd19e3","status":"active","name":"elastic piezoresistive textile","description":"A stretchable textile material whose electrical resistance changes with mechanical strain.","types":["material"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_7793a3d66a265acce4789ecd16cd19e3"},{"public_id":"co_9c79b844cd34814bb36b339e96c8f977","status":"active","name":"sensitivity","description":"A response characteristic describing how strongly a piezoresistive element output changes with applied strain.","types":["performance measure"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_9c79b844cd34814bb36b339e96c8f977"},{"public_id":"co_a4b4905ae57349599c63a5d2cb69838c","status":"active","name":"tachypnea","description":"A rapid breathing condition used during feasibility testing of the smart textile.","types":["experimental condition"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_a4b4905ae57349599c63a5d2cb69838c"},{"public_id":"co_b7d578270487c0f263219057bd532568","status":"active","name":"respiratory monitoring","description":"The measurement of breathing activity through chest movements in the described wearable application.","types":["application"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_b7d578270487c0f263219057bd532568"},{"public_id":"co_cc8bdf8817c5c7f7a9b7bd5c587292f0","status":"active","name":"motion capture system","description":"The reference system used to gather comparison data for respiratory frequency estimation.","types":["reference system"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_cc8bdf8817c5c7f7a9b7bd5c587292f0"},{"public_id":"co_d2b77350fca0243877c756036502154f","status":"active","name":"six piezoresistive elements","description":"The set of sensing components integrated into the smart textile.","types":["sensor configuration"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_d2b77350fca0243877c756036502154f"},{"public_id":"co_d7574fd4b430df07d1b258a4d6376037","status":"active","name":"wearable respiratory monitoring","description":"The use of wearable systems to monitor breathing-related physiological parameters.","types":["application"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_d7574fd4b430df07d1b258a4d6376037"},{"public_id":"co_e1c195bfd9d7c4db9943551216ffb7d0","status":"active","name":"respiratory frequency","description":"The breathing rate estimated from smart textile signals and reference measurements.","types":["physiological parameter"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_e1c195bfd9d7c4db9943551216ffb7d0"},{"public_id":"co_e5b8989c9704efb55c7e7c6eeee0d158","status":"active","name":"average respiratory frequency","description":"The mean breathing frequency used to compare smart textile outputs with reference system values.","types":["outcome measure"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_e5b8989c9704efb55c7e7c6eeee0d158"},{"public_id":"co_ee8db2e497dce6933db3632a85ffbe0a","status":"active","name":"length and width","description":"Geometric dimensions of the piezoresistive elements evaluated for their effect on sensing behavior.","types":["design parameters"],"aliases":[],"contributors":[{"id":136,"public_id":"3c2apqe3ut","public_label":"Anonymous (3c2apqe3ut)","roles":["extraction"],"url":"https://sah.borca.ai/u/3c2apqe3ut"},{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["review"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_ee8db2e497dce6933db3632a85ffbe0a"}],"external_ids":{"DOI":"10.1109/JSEN.2019.2917617","ArXiv":null,"PubMed":null,"PubMedCentral":null,"MAG":2944928173,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/182620577","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":1},"paper_id":630900,"paper_uid":"85d33729-f16c-40b7-8bfc-63c47d6daf9f","canonical_identity":{"paper_id":630900,"paper_uid":"85d33729-f16c-40b7-8bfc-63c47d6daf9f","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/182620577"}