{"corpus_id":204252780,"paper_sha":"9391303fe3f33391d799e615c104c0a95d38ba29","doi":"10.1051/e3sconf/201911600071","arxiv_id":null,"pmid":null,"pmcid":null,"mag_id":2976487561,"dblp_id":null,"acl_id":null,"title":"Characteristics of Oder river water temperature for heat pump","year":2019,"publication_date":null,"venue":"E3S Web of Conferences","journal":{"name":"E3S Web of Conferences","pages":null,"volume":null},"journal_issn":null,"journal_title":null,"publication_types":["Conference"],"pubmed_pub_types":null,"s2_fields_of_study":["Engineering","Environmental Science"],"reference_count":11,"citation_count":5,"influential_citation_count":0,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":1,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"Currently there is increasing interest in using surface water bodies as renewable energy sources for year around or seasonal heating and cooling applications e.g. heat pumps. This paper presents the statistical analysis of average water temperature and the flow rate of the Oder River. Linear regression analysis was carried out on the base of ten years (2005–2014) diurnal water temperatures measurements data. The results determine the relation between average air temperature in Wroclaw and Oder river water average temperature for two analysed locations. The Pearson's r correlation coefficients were determined. Additionally, the variability of water flow rates from 2008–2010 in the annual cycle were illustrated. The article proposes the conceptual framework for surface water bodies technical aspects. This proposition is the first step for wider analysis in order to identify the thermal potential of the Oder river water as heat source for heat pumps.","claims":[{"public_id":"cl_67416a4c26bc384092e79d64b1180c79","status":"active","text":"A conceptual framework addressing the technical aspects of surface water bodies is proposed as a first step toward identifying the thermal potential of Oder river water as a heat source for heat pumps.","confidence":0.85,"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/claims/cl_67416a4c26bc384092e79d64b1180c79"},{"public_id":"cl_221527b5ef27ac63e2efeaa8c559fe63","status":"active","text":"Linear regression analysis of ten years (2005–2014) of diurnal water temperature measurements determines the relation between average air temperature in Wroclaw and Oder river water average temperature at two analysed locations, quantified using Pearson's r correlation coefficients.","confidence":0.9,"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/claims/cl_221527b5ef27ac63e2efeaa8c559fe63"},{"public_id":"cl_85c85d5628b5c6b0aeeb9ef521276946","status":"active","text":"Water flow rates of the Oder River vary across the annual cycle, illustrated using data from 2008–2010.","confidence":0.82,"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/claims/cl_85c85d5628b5c6b0aeeb9ef521276946"}],"concepts":[{"public_id":"co_04037d1e93867bb668885608fb1bba3d","status":"active","name":"Pearson's r correlation coefficient","description":"A statistical measure of linear correlation between two variables, used here to quantify the air-water temperature relation.","types":["measure"],"aliases":["Pearson's r"],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_04037d1e93867bb668885608fb1bba3d"},{"public_id":"co_4d7a9f2099d7d90e2c9be47c63ac9883","status":"active","name":"Oder River","description":"The river studied in this paper for its water temperature and flow rate characteristics.","types":["geographic entity"],"aliases":[],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_4d7a9f2099d7d90e2c9be47c63ac9883"},{"public_id":"co_5d5ade060314a0364a9710e38c0c3565","status":"active","name":"water flow rate","description":"The rate of water flow of the Oder River, analyzed for its annual variability.","types":["measurement"],"aliases":["flow rate"],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_5d5ade060314a0364a9710e38c0c3565"},{"public_id":"co_74cd295f9ff3f372a4d406b7bb828dc1","status":"active","name":"diurnal water temperature measurements","description":"Daily water temperature measurement data collected over a ten-year period from 2005 to 2014.","types":["dataset"],"aliases":[],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_74cd295f9ff3f372a4d406b7bb828dc1"},{"public_id":"co_9499f91d13c6ee14ba11deb08e348005","status":"active","name":"conceptual framework for surface water bodies","description":"A proposed framework addressing the technical aspects of using surface water bodies as thermal energy resources.","types":["framework"],"aliases":[],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_9499f91d13c6ee14ba11deb08e348005"},{"public_id":"co_a7a01577df6d8cf1637821bdec9bad31","status":"active","name":"thermal potential","description":"The capacity of Oder river water to serve as a heat source for heat pump applications.","types":["concept"],"aliases":[],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_a7a01577df6d8cf1637821bdec9bad31"},{"public_id":"co_a7a2be86fa2a10573c7693e3e6e5e220","status":"active","name":"Oder river water temperature","description":"The average water temperature of the Oder River measured at two locations.","types":["measurement"],"aliases":["Oder river water average temperature"],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_a7a2be86fa2a10573c7693e3e6e5e220"},{"public_id":"co_b43681439d0f3145ee5151ac8c4ef7df","status":"active","name":"surface water bodies","description":"Bodies of water such as rivers considered as renewable energy sources for heating and cooling.","types":["resource"],"aliases":[],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_b43681439d0f3145ee5151ac8c4ef7df"},{"public_id":"co_c2ff80876244863cf6fb55df6a3eef4f","status":"active","name":"average air temperature in Wroclaw","description":"The average air temperature recorded in the city of Wroclaw, compared against river water temperature.","types":["measurement"],"aliases":[],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_c2ff80876244863cf6fb55df6a3eef4f"},{"public_id":"co_e75f40010687b33361b3e02652198ebe","status":"active","name":"heat pump","description":"A device that transfers heat from a source, such as river water, for heating and cooling applications.","types":["technology"],"aliases":[],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_e75f40010687b33361b3e02652198ebe"},{"public_id":"co_ea73315d1aa49e0e56cbd12058255248","status":"active","name":"linear regression analysis","description":"A statistical method used to model the relationship between air temperature and river water temperature.","types":["method"],"aliases":[],"contributors":[{"id":17,"public_id":"322360f1c1","public_label":"Killer Whale (322360f1c1)","roles":["extraction"],"url":"https://sah.borca.ai/u/322360f1c1"},{"id":1165,"public_id":"ezd9qvkvax","public_label":"The Reverser‮ (ezd9qvkvax)","roles":["review"],"url":"https://sah.borca.ai/u/ezd9qvkvax"},{"id":171,"public_id":"b9tnx83g25","public_label":"eunsjani (b9tnx83g25)","roles":["review"],"url":"https://sah.borca.ai/u/b9tnx83g25"}],"url":"https://sah.borca.ai/concepts/co_ea73315d1aa49e0e56cbd12058255248"}],"external_ids":{"DOI":"10.1051/e3sconf/201911600071","ArXiv":null,"PubMed":null,"PubMedCentral":null,"MAG":2976487561,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/204252780","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":1},"paper_id":631788,"paper_uid":"62da0a24-3840-4b00-80e8-0cf3ece4801e","canonical_identity":{"paper_id":631788,"paper_uid":"62da0a24-3840-4b00-80e8-0cf3ece4801e","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/204252780"}