{"corpus_id":209178429,"paper_sha":"7cfec4e28f70b06e420004f55581c89fe538106d","doi":"10.3390/su11236867","arxiv_id":null,"pmid":null,"pmcid":null,"mag_id":2994420833,"dblp_id":null,"acl_id":null,"title":"Analysis of the Impact of Selected Parameters of the Hybrid Extinguishing System on the Fire Environment in a Closed Room","year":2019,"publication_date":"2019-12-03","venue":"","journal":{"name":"Sustainability","pages":"6867","volume":"11"},"journal_issn":null,"journal_title":null,"publication_types":[],"pubmed_pub_types":null,"s2_fields_of_study":["Materials Science","Engineering","Environmental Science"],"reference_count":34,"citation_count":5,"influential_citation_count":0,"is_open_access":true,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":1,"s2_open_access_pdf_url":"https://www.mdpi.com/2071-1050/11/23/6867/pdf?version=1575368041","s2_open_access_landing_url":"https://www.semanticscholar.org/paper/7cfec4e28f70b06e420004f55581c89fe538106d","s2_open_access_license":"CCBY","s2_open_access_status":"GOLD","pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"The main purpose of this study was to analyze the impact of some parameters (water mist flow rate and type of gas used) of the hybrid extinguishing system on the fire environment (temperature as well as carbon monoxide and oxygen concentrations) in a closed room. Hybrid fire-extinguishing systems in which water mist is driven by inert gas combine the advantages of typical fog systems and fixed gas extinguishing devices. They have been developed in the last years but are now being used more and more often and the preparation of standards for them is planned for 2020. For this purpose, many fire tests with this system should be conducted. Some of them are discussed in this paper. Two different flow rates of water mist (1.5 or 3 dm3/min) and inert gas (nitrogen or air) were used during hybrid system testing. Some parameters of the fire environment in the compartment such as temperature measured by thermocouples as well as carbon monoxide and oxygen concentrations measured by electrochemical gas sensors are presented here. The characteristic values of the extinguishing process are also included. The assumed times of ensuring safe conditions in the room have been confirmed.","claims":[{"public_id":"cl_e9a84ce9a6c4560204b7cfe254827d4e","status":"active","text":"Tests with 1.5 or 3 dm3/min water mist flow rates and nitrogen or air as the inert gas are used to assess hybrid extinguishing system behavior.","confidence":0.93,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_e9a84ce9a6c4560204b7cfe254827d4e"},{"public_id":"cl_83a0b86f39d135d31c8f06987d1f1bef","status":"active","text":"The assumed times for ensuring safe conditions in the room were confirmed.","confidence":0.9,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_83a0b86f39d135d31c8f06987d1f1bef"},{"public_id":"cl_f34ae8551683aa31bceb62d070af3570","status":"active","text":"Water mist flow rate and the type of driving gas affect the fire environment in a closed room, including temperature and carbon monoxide and oxygen concentrations.","confidence":0.96,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_f34ae8551683aa31bceb62d070af3570"}],"concepts":[{"public_id":"co_10ce79786e0da8239d59a1a6c917115a","status":"active","name":"fire environment in a closed room","description":"The compartment fire conditions characterized by temperature and gas concentrations.","types":["environment"],"aliases":["fire environment"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_10ce79786e0da8239d59a1a6c917115a"},{"public_id":"co_2ab028d323447471c47cb42a799db768","status":"active","name":"air","description":"Ambient air used as one of the gases in the hybrid extinguishing tests.","types":["gas"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_2ab028d323447471c47cb42a799db768"},{"public_id":"co_394320e780c99b7d48e08f3af9736d19","status":"active","name":"carbon monoxide","description":"A toxic combustion gas measured in the compartment during the fire tests.","types":["gas","measurement"],"aliases":["CO"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_394320e780c99b7d48e08f3af9736d19"},{"public_id":"co_4f99a5e2f821c876458830d36d2c2019","status":"active","name":"safe conditions in the room","description":"Room conditions judged acceptable after extinguishing, based on the reported times.","types":["outcome"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_4f99a5e2f821c876458830d36d2c2019"},{"public_id":"co_58296adb53caf7ce6302b30556f5d430","status":"active","name":"extinguishing process","description":"The sequence of events and characteristic values observed during fire suppression.","types":["process"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_58296adb53caf7ce6302b30556f5d430"},{"public_id":"co_6b109362bca14ee3d5c52728bea003d8","status":"active","name":"temperature","description":"The thermal condition in the room measured during extinguishing tests.","types":["measurement"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_6b109362bca14ee3d5c52728bea003d8"},{"public_id":"co_70fa0e4c9863627fe4de74b63ead2d21","status":"active","name":"closed room","description":"A confined compartment used as the experimental fire environment.","types":["environment"],"aliases":["compartment"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_70fa0e4c9863627fe4de74b63ead2d21"},{"public_id":"co_98f7f2ae7d5f0e66ebb10351fbf7d6b4","status":"active","name":"oxygen","description":"A gaseous component of the room atmosphere measured during the fire tests.","types":["gas","measurement"],"aliases":["O2"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_98f7f2ae7d5f0e66ebb10351fbf7d6b4"},{"public_id":"co_bf705bab60288a40544f2f65ee8f3aad","status":"active","name":"nitrogen","description":"An inert gas used as a driving gas in the hybrid extinguishing tests.","types":["gas"],"aliases":["N2"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_bf705bab60288a40544f2f65ee8f3aad"},{"public_id":"co_e2364000633dc4b5b19d3e0c2a171f13","status":"active","name":"water mist flow rate","description":"The rate at which water mist is delivered in the extinguishing system.","types":["parameter"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_e2364000633dc4b5b19d3e0c2a171f13"},{"public_id":"co_f3d9624d59b4c15b99e329a4bd6c632e","status":"active","name":"hybrid extinguishing system","description":"A fire-extinguishing system in which water mist is driven by an inert gas.","types":["method","system"],"aliases":["hybrid fire-extinguishing system"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_f3d9624d59b4c15b99e329a4bd6c632e"},{"public_id":"co_fb859cf59feeee1bf5f899f8c416d544","status":"active","name":"type of gas used","description":"The kind of gas used to drive the water mist in the hybrid extinguishing system.","types":["parameter"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_fb859cf59feeee1bf5f899f8c416d544"}],"external_ids":{"DOI":"10.3390/su11236867","ArXiv":null,"PubMed":null,"PubMedCentral":null,"MAG":2994420833,"DBLP":null,"ACL":null},"open_access":{"is_open_access":true,"pdf_url":"https://www.mdpi.com/2071-1050/11/23/6867/pdf?version=1575368041","landing_url":"https://www.semanticscholar.org/paper/7cfec4e28f70b06e420004f55581c89fe538106d","source":"semantic_scholar","pdf_url_source":"semantic_scholar_open_access_pdf","license":"CCBY","status":"GOLD","reason":null},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":1},"paper_id":630540,"paper_uid":"3f298b3f-b81e-476c-a6cd-7f329b9cb903","canonical_identity":{"paper_id":630540,"paper_uid":"3f298b3f-b81e-476c-a6cd-7f329b9cb903","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/209178429"}