{"corpus_id":213398277,"paper_sha":"53271e460b2dbcd6a0bb76a6e1e945562af212d8","doi":"10.1002/er.5173","arxiv_id":null,"pmid":null,"pmcid":null,"mag_id":3003915116,"dblp_id":null,"acl_id":null,"title":"Exergetic performance and comparative assessment of bottoming power cycles operating with carbon dioxide–based binary mixture as working fluid","year":2020,"publication_date":"2020-01-28","venue":"International Journal of Energy Research","journal":{"name":"International Journal of Energy Research","pages":"7957 - 7973","volume":"44"},"journal_issn":null,"journal_title":null,"publication_types":[],"pubmed_pub_types":null,"s2_fields_of_study":["Engineering","Environmental Science"],"reference_count":70,"citation_count":12,"influential_citation_count":0,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":1,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"This paper presents CO2‐toluene (CO2‐C7H8) binary mixture as working fluid to enhance the energetic and exergetic performance of CO2 bottoming power cycles in warm ambient conditions. A criterion for selection of CO2‐based binary mixture is defined, and 0.9 CO2/0.1 C7H8 composition is decided based on the required minimum cycle temperature compatible with ambient conditions. Bottoming simple regenerative cycle (BSRC) and bottoming preheating cycle (BPHC) configurations are selected, and their realistic operating conditions are determined based on sensitivity analysis. The performance of bottoming cycles using CO2‐C7H8 binary mixture is compared with the bottoming cycles using pure CO2 as working fluid at different ambient temperatures. It is observed that the cycles operating with pure CO2 can only perform better at lower ambient temperature conditions, whereas, at the increased ambient temperatures, bottoming cycles with CO2‐C7H8 binary mixture outperform and produce significant gains in exergetic and energetic performance compared with pure CO2 bottoming cycles. A maximum gain of exergetic efficiency for BSRC and BPHC observed is 26.83% and 18.71%, respectively, at an operating ambient temperature of 313 K, whereas an overall gain in energetic efficiencies for BSRC and BPHC observed is 28.92% and 10.12%, respectively. Taking into consideration thermodynamic performance, overall UA (product of overall heat transfer coefficient and heat transfer area for the heat exchanger) and specific investment cost, BPHC configuration is suggested as reasonable choice for higher ambient temperature conditions.","claims":[{"public_id":"cl_fa87241b7d5a30a318fca6ab76777b84","status":"active","text":"A 0.9 CO2/0.1 C7H8 composition is selected based on the minimum cycle temperature required to remain compatible with ambient conditions.","confidence":0.93,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_fa87241b7d5a30a318fca6ab76777b84"},{"public_id":"cl_1d9891bcebf9b5d2c6ee1ae99069c9a1","status":"active","text":"A CO2–toluene binary mixture improves the energetic and exergetic performance of CO2 bottoming power cycles in warm ambient conditions.","confidence":0.97,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_1d9891bcebf9b5d2c6ee1ae99069c9a1"},{"public_id":"cl_662f007c27dae55a5dd452995ec1994a","status":"active","text":"At 313 K, the maximum exergetic-efficiency gains are 26.83% for the bottoming simple regenerative cycle and 18.71% for the bottoming preheating cycle.","confidence":0.95,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_662f007c27dae55a5dd452995ec1994a"},{"public_id":"cl_166e23a0ea044b55f3013d926609879b","status":"active","text":"At 313 K, the overall energetic-efficiency gains are 28.92% for the bottoming simple regenerative cycle and 10.12% for the bottoming preheating cycle.","confidence":0.95,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_166e23a0ea044b55f3013d926609879b"},{"public_id":"cl_cb5b123b7d66bd8244fb64e340512681","status":"active","text":"At higher ambient temperatures, bottoming cycles with the CO2–toluene binary mixture outperform pure CO2 bottoming cycles, while pure CO2 cycles perform better only at lower ambient temperatures.","confidence":0.96,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_cb5b123b7d66bd8244fb64e340512681"},{"public_id":"cl_01cd0026682e77e374707318badeb671","status":"active","text":"Considering thermodynamic performance, overall UA, and specific investment cost, the bottoming preheating cycle is suggested as the reasonable choice for higher ambient temperature conditions.","confidence":0.9,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_01cd0026682e77e374707318badeb671"}],"concepts":[{"public_id":"co_09bdd2a0295e58def782d26b14c4ba50","status":"active","name":"minimum cycle temperature","description":"The lowest cycle temperature considered in selecting a mixture composition compatible with ambient conditions.","types":["thermodynamic parameter"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_09bdd2a0295e58def782d26b14c4ba50"},{"public_id":"co_0d7f8fcf6b6e0bb048f6f150dc93c3b0","status":"active","name":"overall UA","description":"The product of the overall heat transfer coefficient and heat transfer area for a heat exchanger.","types":["heat transfer parameter","design metric"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_0d7f8fcf6b6e0bb048f6f150dc93c3b0"},{"public_id":"co_35c5b597f36fb31ae0da724683da2c32","status":"active","name":"specific investment cost","description":"The investment cost normalized by unit capacity or output for the cycle system.","types":["economic metric"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_35c5b597f36fb31ae0da724683da2c32"},{"public_id":"co_3ec86d0d138024770e0c5b1054644bee","status":"active","name":"exergetic efficiency","description":"A measure of how effectively a cycle converts available work potential into useful output.","types":["performance metric"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_3ec86d0d138024770e0c5b1054644bee"},{"public_id":"co_67ee9ad4b3313b806fe172119b4dda05","status":"active","name":"CO2–toluene binary mixture","description":"A working fluid mixture of carbon dioxide and toluene used in the bottoming power cycles.","types":["working fluid","mixture"],"aliases":["CO2-C7H8 binary mixture","CO2–C7H8 binary mixture"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_67ee9ad4b3313b806fe172119b4dda05"},{"public_id":"co_82f40f0725a823e493b0241f73f62a34","status":"active","name":"bottoming simple regenerative cycle","description":"A bottoming power-cycle configuration that includes regenerative heat recovery.","types":["cycle configuration","power cycle"],"aliases":["BSRC"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_82f40f0725a823e493b0241f73f62a34"},{"public_id":"co_84b29e9daef5e11be5f249bccd4c8d36","status":"active","name":"warm ambient conditions","description":"Operating conditions with elevated surrounding temperature relevant to cycle performance.","types":["operating condition"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_84b29e9daef5e11be5f249bccd4c8d36"},{"public_id":"co_a401474afe67bca7b9cafadde93c2d34","status":"active","name":"0.9 CO2/0.1 C7H8 composition","description":"A specific binary-mixture composition containing 90% carbon dioxide and 10% toluene by fraction.","types":["composition"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_a401474afe67bca7b9cafadde93c2d34"},{"public_id":"co_acfc7b1f4f90158bdf2d3d27d610473c","status":"active","name":"pure CO2","description":"Carbon dioxide used alone as the working fluid for comparison with the binary mixture.","types":["working fluid"],"aliases":["pure carbon dioxide"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_acfc7b1f4f90158bdf2d3d27d610473c"},{"public_id":"co_b7d58ecb52ce988255c26d193762c42e","status":"active","name":"ambient conditions","description":"The surrounding environmental conditions used to set the cycle operating constraints.","types":["operating condition"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_b7d58ecb52ce988255c26d193762c42e"},{"public_id":"co_d09beeeece23a490096e716879cc7c4c","status":"active","name":"ambient temperature","description":"The surrounding temperature level used to compare cycle performance across operating cases.","types":["operating condition","temperature"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_d09beeeece23a490096e716879cc7c4c"},{"public_id":"co_eb5ba0f1694181d2d862d31573b50dcc","status":"active","name":"bottoming preheating cycle","description":"A bottoming power-cycle configuration that includes preheating before expansion or power conversion.","types":["cycle configuration","power cycle"],"aliases":["BPHC"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_eb5ba0f1694181d2d862d31573b50dcc"},{"public_id":"co_f12671e1b903e55babe911ce1168f800","status":"active","name":"CO2 bottoming power cycles","description":"Bottoming power-cycle systems that use carbon dioxide as the working fluid.","types":["power cycle","thermodynamic system"],"aliases":["CO2 bottoming cycles"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_f12671e1b903e55babe911ce1168f800"},{"public_id":"co_fa6cc1230168e37c0c98b204d1702542","status":"active","name":"energetic efficiency","description":"A measure of how effectively a cycle converts input energy into useful output.","types":["performance metric"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_fa6cc1230168e37c0c98b204d1702542"}],"external_ids":{"DOI":"10.1002/er.5173","ArXiv":null,"PubMed":null,"PubMedCentral":null,"MAG":3003915116,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/213398277","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":1},"paper_id":632149,"paper_uid":"9c70ba56-ba2d-4daf-9d5d-78567bca4b94","canonical_identity":{"paper_id":632149,"paper_uid":"9c70ba56-ba2d-4daf-9d5d-78567bca4b94","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/213398277"}