{"corpus_id":270718456,"paper_sha":"98e257527daf41e4b99513ca3e0629c52619453f","doi":"10.1109/TSTE.2024.3418147","arxiv_id":null,"pmid":null,"pmcid":null,"mag_id":null,"dblp_id":null,"acl_id":null,"title":"Fault Current Multi-Stages Calculation Method for DFIG-Based Wind Farms With Whole Fault Process Attributes Under Asymmetrical Grid Fault Conditions","year":2024,"publication_date":"2024-10-01","venue":"IEEE Transactions on Sustainable Energy","journal":{"name":"IEEE Transactions on Sustainable Energy","pages":"2361-2379","volume":"15"},"journal_issn":null,"journal_title":null,"publication_types":["JournalArticle"],"pubmed_pub_types":null,"s2_fields_of_study":[],"reference_count":46,"citation_count":7,"influential_citation_count":0,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":1,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"The existing imprecise fault current calculation, due to incomplete stage division of whole fault process of DFIG-based wind farms (DBWFs), brings great hidden dangers to safety and stable operation of local grid. To tackle this challenge, a fault current multi-stages calculation (FCMSC) method is proposed to accurately calculate DFIG-based wind farm's output symmetrical and asymmetrical fault currents under grid whole fault process that including fault occurrence, fault ride-through and fault recovery. The main content of FCMSC method includes: 1) Whole fault process equivalent aggregation model, which contains protection response stage, first crowbar protection stage, demagnetization operation stage, reactive current injection stage, and second crowbar protection stage, is completely established while second crowbar protection stage is firstly dissected in detail. 2) Fault current contribution mechanism, considering wind speed, is revealed to have GSC injection and absorption modes under asymmetrical grid fault conditions. 3) Fault current universal expression, which covers whole fault process operation stages and scenarios, is conducted by replacing differential equations with simple algebraic operations for improving calculation accuracy, timeliness and universality. 4) Fault current characteristic components, which contain DC components, AC stable components, and AC attenuated components, is extracted for providing key data for fault identification and protection. Extensive test results under symmetrical and asymmetrical faults are illustrated for verifying the correctness of proposed FCMSC method.","claims":[{"public_id":"cl_ee264e7f160c1d1263b6296e74da2949","status":"active","text":"A fault current multi-stages calculation method is proposed to accurately calculate symmetrical and asymmetrical fault currents of DFIG-based wind farms across fault occurrence, fault ride-through, and fault recovery.","confidence":0.98,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_ee264e7f160c1d1263b6296e74da2949"},{"public_id":"cl_99562b22383b68f2d930a4281bf1c657","status":"active","text":"A universal fault current expression is derived by replacing differential equations with algebraic operations to improve calculation accuracy, timeliness, and universality, and fault current characteristic components are extracted for fault identification and protection.","confidence":0.93,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_99562b22383b68f2d930a4281bf1c657"},{"public_id":"cl_961942bd5ef880c9838ff1996bf798f3","status":"active","text":"A whole fault process equivalent aggregation model is established with protection response, first crowbar protection, demagnetization operation, reactive current injection, and second crowbar protection stages.","confidence":0.95,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_961942bd5ef880c9838ff1996bf798f3"},{"public_id":"cl_472973e365310319c5c3474cc07258a0","status":"active","text":"Fault current contribution under asymmetrical grid fault conditions depends on wind speed and includes GSC injection and absorption modes.","confidence":0.94,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_472973e365310319c5c3474cc07258a0"},{"public_id":"cl_6ff7360104b9aa69b9b6eda1da7a7611","status":"active","text":"The second crowbar protection stage is dissected in detail for the first time in the described model.","confidence":0.91,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_6ff7360104b9aa69b9b6eda1da7a7611"}],"concepts":[{"public_id":"co_036eb0823516e39569c42642a4dabfca","status":"active","name":"whole fault process equivalent aggregation model","description":"An equivalent model that aggregates the fault process into distinct operating stages for current calculation.","types":["model"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_036eb0823516e39569c42642a4dabfca"},{"public_id":"co_0d99ddcec47fbedd27bb2aea2fdaab72","status":"active","name":"demagnetization operation stage","description":"The stage in which demagnetization is applied during fault handling.","types":["process stage"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_0d99ddcec47fbedd27bb2aea2fdaab72"},{"public_id":"co_1cd145602ae01490cbe9b830449e5572","status":"active","name":"reactive current injection stage","description":"The stage in which reactive current is injected into the grid during fault ride-through.","types":["process stage"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_1cd145602ae01490cbe9b830449e5572"},{"public_id":"co_1cde710ed72aba8395467c7872bb6028","status":"active","name":"first crowbar protection stage","description":"The initial crowbar protection phase in the fault process of a doubly fed induction generator wind farm.","types":["process stage"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_1cde710ed72aba8395467c7872bb6028"},{"public_id":"co_1cf13f42f3e44d77e6d1e4e27d36f08e","status":"active","name":"fault current characteristic components","description":"The identifiable components of fault current used to characterize fault behavior.","types":["signal components"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_1cf13f42f3e44d77e6d1e4e27d36f08e"},{"public_id":"co_25ef28eda28a391f887f28fa35785c98","status":"active","name":"DFIG-based wind farms","description":"Wind farms built from doubly fed induction generator units.","types":["system"],"aliases":["DBWFs"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_25ef28eda28a391f887f28fa35785c98"},{"public_id":"co_509e2a265ba741472cfb4d88bf3264cd","status":"active","name":"GSC injection and absorption modes","description":"Two operating modes of the grid-side converter in which it injects or absorbs current during faults.","types":["operating mode"],"aliases":["GSC modes"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_509e2a265ba741472cfb4d88bf3264cd"},{"public_id":"co_69c24ecb762d6e0bc2d4624259acd508","status":"active","name":"fault current contribution mechanism","description":"The mechanism describing how different components contribute to fault current during asymmetrical grid faults.","types":["mechanism"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_69c24ecb762d6e0bc2d4624259acd508"},{"public_id":"co_b0ad16d69e96c9d53302c2b4fedebbf1","status":"active","name":"wind speed","description":"The airflow condition that influences the wind turbine operating state and fault current contribution.","types":["operating condition"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_b0ad16d69e96c9d53302c2b4fedebbf1"},{"public_id":"co_b84dedc9b07bb5abba017f8bee19c411","status":"active","name":"whole fault process","description":"The complete sequence of fault occurrence, fault ride-through, and fault recovery.","types":["process"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_b84dedc9b07bb5abba017f8bee19c411"},{"public_id":"co_bc5976d59ceb3badba9faf5b6500351b","status":"active","name":"fault current universal expression","description":"A general algebraic expression for fault current that covers multiple operating stages and fault scenarios.","types":["formula"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_bc5976d59ceb3badba9faf5b6500351b"},{"public_id":"co_cbd378c8b0e9602176b024c55207085c","status":"active","name":"fault current multi-stages calculation method","description":"A calculation approach that divides the fault process into multiple stages to compute fault currents in a wind farm.","types":["method"],"aliases":["FCMSC"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_cbd378c8b0e9602176b024c55207085c"},{"public_id":"co_ea875bb54d53d964445621d4842e385b","status":"active","name":"second crowbar protection stage","description":"A later crowbar protection phase that is analyzed in detail within the fault process model.","types":["process stage"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_ea875bb54d53d964445621d4842e385b"},{"public_id":"co_f22c20e65908094da406d810f0dcadf7","status":"active","name":"protection response stage","description":"The stage in which protection actions respond to the fault.","types":["process stage"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_f22c20e65908094da406d810f0dcadf7"},{"public_id":"co_f5bacc51342f45bd29c658a928a46275","status":"active","name":"fault identification and protection","description":"Protection-related use of extracted fault current features to detect and respond to faults.","types":["application"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_f5bacc51342f45bd29c658a928a46275"}],"external_ids":{"DOI":"10.1109/TSTE.2024.3418147","ArXiv":null,"PubMed":null,"PubMedCentral":null,"MAG":null,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/270718456","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":1},"paper_id":631163,"paper_uid":"3fbcde7e-c38e-4b99-951a-f4b10568fdbe","canonical_identity":{"paper_id":631163,"paper_uid":"3fbcde7e-c38e-4b99-951a-f4b10568fdbe","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/270718456"}