{"corpus_id":40905094,"paper_sha":"9674688076cb6c0e271eefb524ec39a17e0b6332","doi":"10.1109/JSEN.2015.2487602","arxiv_id":null,"pmid":null,"pmcid":null,"mag_id":2239156137,"dblp_id":null,"acl_id":null,"title":"Inspection of Cylindrical Structures Using the First Longitudinal Guided Wave Mode in Isolation for Higher Flaw Sensitivity","year":2016,"publication_date":"2016-02-01","venue":"IEEE Sensors Journal","journal":{"name":"IEEE Sensors Journal","pages":"706-714","volume":"16"},"journal_issn":null,"journal_title":null,"publication_types":[],"pubmed_pub_types":null,"s2_fields_of_study":["Materials Science","Engineering"],"reference_count":29,"citation_count":38,"influential_citation_count":0,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":1,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"Less attention has been given to the inspection using the first longitudinal guided wave mode due to its attenuative and dispersive properties at commonly used ultrasonic guided waves (UGWs) operating frequency region (20-100 kHz). However, the first longitudinal guided wave mode has higher flaw sensitivity due to having a shorter wave length and having higher number of non-axisymmetric wave modes at a given frequency. This enhances the capabilities of advanced UGW techniques which require higher number of non-axisymmetric modes. This study has been performed to investigate the potential of mode purity and flaw sensitivity of the first longitudinal guided wave mode compared with other axisymmetric modes in the UGW operating frequency region. Numerical and experimental investigation have been conducted to investigate pure excitation and flaw sensitivity of the first longitudinal guided wave mode. It has been validated that the first longitudinal guided wave mode can be used in the UGW inspection effectively in isolation by adopting transducers with out-of-plane vibration. This reduces the cost and the weight of the UGW inspection tooling. The flaw sensitivity of the first longitudinal guided wave mode has been investigated by aid of an empirically validated UGW focusing technique. Under the studied conditions in this paper, the first longitudinal guided wave mode has $\\sim5$ times higher flaw sensitivity compared with the second longitudinal guided wave mode and $\\sim 2.5$ times higher than the first torsional guided wave mode. This enhances the capability of UGW flaw detection and sizing.","claims":[{"public_id":"cl_51f8ba68252d9cd2486e021677726442","status":"active","text":"An empirically validated ultrasonic guided wave focusing technique was used to investigate flaw sensitivity.","confidence":0.86,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_51f8ba68252d9cd2486e021677726442"},{"public_id":"cl_39af0e9b364083eb6d8e92165ee15fba","status":"active","text":"The first longitudinal guided wave mode can be used effectively in isolation for ultrasonic guided wave inspection by adopting transducers with out-of-plane vibration.","confidence":0.97,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_39af0e9b364083eb6d8e92165ee15fba"},{"public_id":"cl_cf34e2b521886acd41e3ea574da39e96","status":"active","text":"Under the studied conditions, the first longitudinal guided wave mode shows approximately five times higher flaw sensitivity than the second longitudinal guided wave mode and approximately 2.5 times higher than the first torsional guided wave mode.","confidence":0.98,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_cf34e2b521886acd41e3ea574da39e96"},{"public_id":"cl_52112139370fe8a2a1af22a4b661aa44","status":"active","text":"Using the first longitudinal guided wave mode reduces the cost and weight of ultrasonic guided wave inspection tooling.","confidence":0.9,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_52112139370fe8a2a1af22a4b661aa44"}],"concepts":[{"public_id":"co_01f16ced83c4e31e33cbdddbaa073053","status":"active","name":"flaw sensitivity","description":"The ability of an inspection mode or method to detect defects.","types":["measurement property"],"aliases":["defect sensitivity"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_01f16ced83c4e31e33cbdddbaa073053"},{"public_id":"co_0e9f7d83719f09288b8a857da8394e7f","status":"active","name":"first longitudinal guided wave mode","description":"The first longitudinal axisymmetric guided wave mode used for inspecting cylindrical structures.","types":["wave mode"],"aliases":["first longitudinal mode"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_0e9f7d83719f09288b8a857da8394e7f"},{"public_id":"co_199b308fbc63a8d931d210aed6e28245","status":"active","name":"first torsional guided wave mode","description":"The first torsional axisymmetric guided wave mode considered for comparison.","types":["wave mode"],"aliases":["first torsional mode"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_199b308fbc63a8d931d210aed6e28245"},{"public_id":"co_34769d76ac5dfb10aa216fbf66c7bef0","status":"active","name":"ultrasonic guided wave inspection tooling","description":"The hardware and support equipment used to perform guided wave inspection.","types":["equipment"],"aliases":["UGW inspection tooling"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_34769d76ac5dfb10aa216fbf66c7bef0"},{"public_id":"co_c19303c6d3fa5a0a63a7f8ea804f5d55","status":"active","name":"second longitudinal guided wave mode","description":"The second longitudinal axisymmetric guided wave mode considered for comparison.","types":["wave mode"],"aliases":["second longitudinal mode"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_c19303c6d3fa5a0a63a7f8ea804f5d55"},{"public_id":"co_f64ded021a618081d1ca1dca42b7e193","status":"active","name":"transducers with out-of-plane vibration","description":"Transducers designed to excite vibration components perpendicular to the surface plane.","types":["transducer"],"aliases":[],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_f64ded021a618081d1ca1dca42b7e193"},{"public_id":"co_faf830536d27392c15662a64847067a5","status":"active","name":"ultrasonic guided wave inspection","description":"An inspection approach that uses guided ultrasonic waves to evaluate cylindrical structures.","types":["inspection method"],"aliases":["UGW inspection"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_faf830536d27392c15662a64847067a5"},{"public_id":"co_fe16f916dca1a6cd22c636df2f282c45","status":"active","name":"empirically validated ultrasonic guided wave focusing technique","description":"A guided wave focusing method supported by experimental validation in the study.","types":["method"],"aliases":["UGW focusing technique"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_fe16f916dca1a6cd22c636df2f282c45"}],"external_ids":{"DOI":"10.1109/JSEN.2015.2487602","ArXiv":null,"PubMed":null,"PubMedCentral":null,"MAG":2239156137,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/40905094","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":1},"paper_id":633379,"paper_uid":"1af4b535-6456-4713-8542-4eb03bf7cd7f","canonical_identity":{"paper_id":633379,"paper_uid":"1af4b535-6456-4713-8542-4eb03bf7cd7f","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/40905094"}