{"corpus_id":41048029,"paper_sha":"e66b5be3639bac48c4f5cd5a8de7a5dea4385b8e","doi":"10.5301/jva.5000334","arxiv_id":null,"pmid":25634152,"pmcid":null,"mag_id":2048921200,"dblp_id":null,"acl_id":null,"title":"Efficacy and Ease of Use of an Intravenous Catheter Designed to Prevent Blood Leakage: A Prospective Observational Trial","year":2015,"publication_date":"2015-01-27","venue":"Journal of Vascular Access","journal":{"name":"The Journal of Vascular Access","pages":"233 - 236","volume":"16"},"journal_issn":null,"journal_title":null,"publication_types":["Study","JournalArticle"],"pubmed_pub_types":["Journal Article","Observational Study"],"s2_fields_of_study":["Medicine"],"reference_count":8,"citation_count":4,"influential_citation_count":0,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":[{"d":"Catheterization, Peripheral","mj":false,"qs":[{"q":"adverse effects","mj":false,"ui":"Q000009"},{"q":"instrumentation","mj":true,"ui":"Q000295"}],"ui":"D002406"},{"d":"Catheters, Indwelling","mj":true,"ui":"D002408"},{"d":"Equipment Design","mj":false,"ui":"D004867"},{"d":"Germany","mj":false,"ui":"D005858"},{"d":"Hemorrhage","mj":false,"qs":[{"q":"etiology","mj":false,"ui":"Q000209"},{"q":"prevention & control","mj":true,"ui":"Q000517"}],"ui":"D006470"},{"d":"Humans","mj":false,"ui":"D006801"},{"d":"Occupational Exposure","mj":false,"qs":[{"q":"adverse effects","mj":false,"ui":"Q000009"},{"q":"prevention & control","mj":true,"ui":"Q000517"}],"ui":"D016273"},{"d":"Occupational Health","mj":false,"ui":"D016272"},{"d":"Prospective Studies","mj":false,"ui":"D011446"},{"d":"Risk Factors","mj":false,"ui":"D012307"},{"d":"Time Factors","mj":false,"ui":"D013997"},{"d":"Treatment Outcome","mj":false,"ui":"D016896"},{"d":"Vascular Access Devices","mj":true,"ui":"D062666"}],"chemicals":null,"comments_corrections":null,"source_flags":5,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"Purpose Conventional safety intravenous (IV) catheters prevent blood exposure during catheter placement but blood leakage from the unconnected catheter still frequently occurs. In the current study a new safety IV catheter equipped with a blood leakage control septum was assessed under routine clinical conditions. Methods This prospective observational trial was conducted at the KKRN (Katholisches Klinikum Ruhrgebiet Nord), Germany, September/October 2012. Peripheral IV access was established in presurgical patients using either the investigational (“IS3”) or a conventional safety IV catheter (“IS”). Incidence of blood leakage during placement and subsequent (dis-)connection procedures, duration of placement as well as handling conditions were compared. Results A total of 200 IV accesses were established (n(IS3) = 102 and n(IS) = 98). Blood leakage during catheter placement (4.9% (IS3) vs. 61.2% (IS); p<0.001) and blood contaminations (3.9% (IS3) vs. 14.3% (IS); p = 0.01) were significantly reduced for IS3. All blood leakages observed with IS3 were due to improper technique. No blood leakage occurred during repeated (dis-)connections of IS3 (blood leakage IS: 74%). Using IS3, vein compression was not required (no compression: 98%) and duration of catheter placement was significantly shorter (t(IS3) = 69.6 ± 22.4 s vs. t(IS) = 85.2 ± 28.2 s; p<0.001). Conclusions The investigational IV catheter effectively prevented blood leakage, thereby reducing contamination risk and workload associated with cleaning. Omission of vein compression facilitated and shortened IV catheter placement.","claims":[{"public_id":"cl_f5057261ecba3152363ef04f9d46df4f","status":"active","text":"Blood contaminations were significantly reduced with the investigational catheter (3.9% vs. 14.3%).","confidence":0.95,"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_f5057261ecba3152363ef04f9d46df4f"},{"public_id":"cl_4b0dff1fa3ce85d5d77539e4183f8874","status":"active","text":"No blood leakage occurred during repeated (dis-)connections of the investigational catheter, whereas the conventional catheter had 74% blood leakage during such procedures.","confidence":0.95,"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_4b0dff1fa3ce85d5d77539e4183f8874"},{"public_id":"cl_f687477e31d9cbc56b54cd5fabfbb2da","status":"active","text":"The investigational IV catheter (IS3) reduced blood leakage during catheter placement to 4.9% compared to 61.2% for the conventional safety IV catheter (IS).","confidence":0.95,"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_f687477e31d9cbc56b54cd5fabfbb2da"},{"public_id":"cl_1f2259fc1d520ab6d87ff685aa0fe923","status":"active","text":"Using the investigational catheter, vein compression was not required in 98% of placements, and duration of catheter placement was significantly shorter (69.6 ± 22.4 s vs. 85.2 ± 28.2 s).","confidence":0.95,"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_1f2259fc1d520ab6d87ff685aa0fe923"}],"concepts":[{"public_id":"co_0e058e312431f2e8b54b5047cc8d71e9","status":"active","name":"blood leakage during (dis-)connections","description":"Incidence of blood leakage when connecting or disconnecting the catheter.","types":["outcome"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_0e058e312431f2e8b54b5047cc8d71e9"},{"public_id":"co_2c04068a6e5dab6c536ddbe75749f98d","status":"active","name":"conventional safety IV catheter (IS)","description":"A standard safety IV catheter used as comparator, which prevents blood exposure during placement but allows blood leakage from the unconnected catheter.","types":["device"],"aliases":["IS"],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_2c04068a6e5dab6c536ddbe75749f98d"},{"public_id":"co_52cdfb6461b64758091d09aaf05261f7","status":"active","name":"vein compression","description":"Manual compression of the vein during catheter placement to reduce blood leakage.","types":["procedure"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_52cdfb6461b64758091d09aaf05261f7"},{"public_id":"co_747332c6f817f59c90ae0d243089b247","status":"active","name":"blood leakage during catheter placement","description":"Incidence of blood escaping from the catheter during the insertion procedure.","types":["outcome"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_747332c6f817f59c90ae0d243089b247"},{"public_id":"co_78be727cc4e2af9384d5646bdf76f140","status":"active","name":"blood contaminations","description":"Instances where blood contamination occurred during catheter handling.","types":["outcome"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_78be727cc4e2af9384d5646bdf76f140"},{"public_id":"co_882b06f02354be4b79f8cd36a370a76f","status":"active","name":"duration of catheter placement","description":"Time required to successfully place the IV catheter, measured in seconds.","types":["outcome"],"aliases":[],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_882b06f02354be4b79f8cd36a370a76f"},{"public_id":"co_8b81bf2d6ea0246f45d1907c5375a842","status":"active","name":"investigational IV catheter (IS3)","description":"A new safety IV catheter equipped with a blood leakage control septum, designed to prevent blood leakage.","types":["device"],"aliases":["IS3"],"contributors":[{"id":32,"public_id":"7c402c1b98","public_label":"뀨 (7c402c1b98)","roles":["extraction"],"url":"https://sah.borca.ai/u/7c402c1b98"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_8b81bf2d6ea0246f45d1907c5375a842"}],"external_ids":{"DOI":"10.5301/jva.5000334","ArXiv":null,"PubMed":25634152,"PubMedCentral":null,"MAG":2048921200,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/41048029","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":5},"paper_id":634389,"paper_uid":"4eaa8930-8c6c-4948-9260-b2713812cc37","canonical_identity":{"paper_id":634389,"paper_uid":"4eaa8930-8c6c-4948-9260-b2713812cc37","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/41048029"}