{"corpus_id":5483689,"paper_sha":"8e71f4710bc97c9e6e1e1edb5eea48e533a3513d","doi":"10.4103/0971-3026.184409","arxiv_id":null,"pmid":27413269,"pmcid":"4931781","mag_id":2460632351,"dblp_id":null,"acl_id":null,"title":"Imaging of common breast implants and implant-related complications: A pictorial essay","year":2016,"publication_date":"2016-04-01","venue":"Indian Journal of Radiology and Imaging","journal":{"name":"The Indian Journal of Radiology & Imaging","pages":"216 - 225","volume":"26"},"journal_issn":null,"journal_title":null,"publication_types":["JournalArticle"],"pubmed_pub_types":["Journal Article"],"s2_fields_of_study":["Medicine"],"reference_count":17,"citation_count":38,"influential_citation_count":2,"is_open_access":false,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":5,"s2_open_access_pdf_url":null,"s2_open_access_landing_url":null,"s2_open_access_license":null,"s2_open_access_status":null,"pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"Abstract The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.","claims":[{"public_id":"cl_a8fc26b0b4b6b92970ee6499547da25a","status":"active","text":"Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants.","confidence":0.9,"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_a8fc26b0b4b6b92970ee6499547da25a"},{"public_id":"cl_ecaba27b8fc96435537aa109eca99592","status":"active","text":"Magnetic resonance imaging of silicone breast implants has high sensitivity and specificity for detecting implant rupture and is the most reliable modality to assess implant integrity.","confidence":0.95,"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_ecaba27b8fc96435537aa109eca99592"},{"public_id":"cl_6e9b2efe42038ae1ccb9c47129148be7","status":"active","text":"The overall aim of imaging breast implants is to provide pertinent information about implant integrity, detect implant failures, and detect breast conditions unrelated to the implants, such as cancer.","confidence":0.85,"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_6e9b2efe42038ae1ccb9c47129148be7"}],"concepts":[{"public_id":"co_08cc060a88e49b5e1eecfa67d3d70454","status":"active","name":"implant rupture","description":"A failure of the breast implant where the shell breaks, detectable by MRI with high accuracy.","types":["complication"],"aliases":[],"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_08cc060a88e49b5e1eecfa67d3d70454"},{"public_id":"co_1fcc0a7c68b0a2d6af7ee9679d35d8a2","status":"active","name":"implant failures","description":"Any structural or functional failure of a breast implant, including rupture or other abnormalities.","types":["complication"],"aliases":[],"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_1fcc0a7c68b0a2d6af7ee9679d35d8a2"},{"public_id":"co_41e64db3c42df254cc004aa0e731f0c2","status":"active","name":"breast conditions unrelated to implants","description":"Breast pathologies such as cancer that are detected during imaging of breast implants.","types":["clinical condition"],"aliases":[],"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_41e64db3c42df254cc004aa0e731f0c2"},{"public_id":"co_66a1da4f7bd4cfd29ad0cafb4a008a1d","status":"active","name":"imaging breast implants","description":"The overall process of using diagnostic imaging to assess implant integrity, detect failures, and find unrelated breast conditions.","types":["clinical procedure"],"aliases":[],"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_66a1da4f7bd4cfd29ad0cafb4a008a1d"},{"public_id":"co_9e15d2a53db479e610d426bf596b0311","status":"active","name":"implant integrity","description":"The structural intactness of a breast implant, assessed by imaging modalities.","types":["assessment target"],"aliases":[],"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_9e15d2a53db479e610d426bf596b0311"},{"public_id":"co_a115dc4c305af9477438988ad0f500be","status":"active","name":"magnetic resonance imaging","description":"MRI used for evaluating breast implant integrity and detecting implant-related complications.","types":["imaging modality"],"aliases":[],"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_a115dc4c305af9477438988ad0f500be"},{"public_id":"co_ce7cdaa855f638900de0260b4188e17e","status":"active","name":"magnetic resonance imaging of silicone breast implants","description":"MRI specifically used for silicone breast implants, offering high sensitivity and specificity for detecting rupture.","types":["imaging modality"],"aliases":[],"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_ce7cdaa855f638900de0260b4188e17e"},{"public_id":"co_de5f55595f32a0284d382f958ac5b967","status":"active","name":"ultrasonography","description":"Ultrasound imaging used to evaluate breast implants and detect abnormalities.","types":["imaging modality"],"aliases":[],"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_de5f55595f32a0284d382f958ac5b967"},{"public_id":"co_e1cc665637e0f88dbc07a70f695e0917","status":"active","name":"mammography","description":"An X-ray imaging modality used to evaluate breast implants and detect breast conditions.","types":["imaging modality"],"aliases":[],"contributors":[{"id":62,"public_id":"513602784d","public_label":"Anonymous (513602784d)","roles":["extraction"],"url":"https://sah.borca.ai/u/513602784d"},{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["review"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_e1cc665637e0f88dbc07a70f695e0917"}],"external_ids":{"DOI":"10.4103/0971-3026.184409","ArXiv":null,"PubMed":27413269,"PubMedCentral":"4931781","MAG":2460632351,"DBLP":null,"ACL":null},"open_access":{"is_open_access":false,"pdf_url":null,"landing_url":"https://sah.borca.ai/papers/5483689","source":null,"pdf_url_source":null,"license":null,"reason":"pdf_url_not_indexed"},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":5},"paper_id":633321,"paper_uid":"7f7037d5-14bb-40da-942f-4bb8a3afd446","canonical_identity":{"paper_id":633321,"paper_uid":"7f7037d5-14bb-40da-942f-4bb8a3afd446","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/5483689"}