{"corpus_id":99602955,"paper_sha":"c2aaf021f9f0b20c55a637c8a964d1f8963ce57f","doi":"10.1063/1.4975794","arxiv_id":null,"pmid":null,"pmcid":null,"mag_id":2587618232,"dblp_id":null,"acl_id":null,"title":"Analysis and modeling of leakage current sensor under pulsating direct current","year":2017,"publication_date":"2017-02-06","venue":"","journal":{"name":"AIP Advances","pages":"056649","volume":"7"},"journal_issn":null,"journal_title":null,"publication_types":[],"pubmed_pub_types":null,"s2_fields_of_study":["Physics","Chemistry","Engineering"],"reference_count":10,"citation_count":1,"influential_citation_count":0,"is_open_access":true,"arxiv_categories":null,"arxiv_license":null,"arxiv_journal_ref":null,"mesh_headings":null,"chemicals":null,"comments_corrections":null,"source_flags":1,"s2_open_access_pdf_url":"https://aip.scitation.org/doi/pdf/10.1063/1.4975794","s2_open_access_landing_url":"https://www.semanticscholar.org/paper/c2aaf021f9f0b20c55a637c8a964d1f8963ce57f","s2_open_access_license":"CCBY","s2_open_access_status":"GOLD","pmc_open_access_pdf_url":null,"pmc_open_access_landing_url":null,"pmc_open_access_license":null,"pmc_open_access_status":null,"unpaywall_open_access_pdf_url":null,"unpaywall_open_access_landing_url":null,"unpaywall_open_access_license":null,"unpaywall_open_access_status":null,"abstract":"In this paper, the transformation characteristics of current sensor under pulsating DC leakage current is investigated. The mathematical model of current sensor is proposed to accurately describe the secondary side current and excitation current. The transformation process of current sensor is illustrated in details and the transformation error is analyzed from multi aspects. A simulation model is built and a sensor prototype is designed to conduct comparative evaluation, and both simulation and experimental results are presented to verify the correctness of theoretical analysis.","claims":[{"public_id":"cl_715c3426e8dcf16cdca5e2f4d23dbbec","status":"active","text":"A mathematical model of the current sensor is proposed to describe the secondary-side current and excitation current under pulsating DC leakage current.","confidence":0.96,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_715c3426e8dcf16cdca5e2f4d23dbbec"},{"public_id":"cl_ad42112ef3d0f272650a513d7afd407f","status":"active","text":"Simulation and prototype experiments provide comparative evidence that supports the correctness of the theoretical analysis.","confidence":0.9,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_ad42112ef3d0f272650a513d7afd407f"},{"public_id":"cl_88d48bcd743fcf10285ed7bb37f8c6ac","status":"active","text":"The transformation process of the current sensor is analyzed in detail and the transformation error is examined from multiple aspects.","confidence":0.92,"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/claims/cl_88d48bcd743fcf10285ed7bb37f8c6ac"}],"concepts":[{"public_id":"co_0e17ee34c01a7b81f2959d18df373b0c","status":"active","name":"pulsating DC leakage current","description":"A leakage current with a pulsating direct-current waveform used as the operating condition in the study.","types":["signal condition"],"aliases":["pulsating direct current","pulsating DC"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_0e17ee34c01a7b81f2959d18df373b0c"},{"public_id":"co_16f5c56aa88ff3f6d31e905a9d4f4b44","status":"active","name":"transformation error","description":"The error arising during the sensor's current transformation or conversion process.","types":["error measure"],"aliases":["conversion error"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_16f5c56aa88ff3f6d31e905a9d4f4b44"},{"public_id":"co_1aef1ca08693e4ec5d8ff87ce66d9e63","status":"active","name":"excitation current","description":"The magnetizing current associated with the sensor's excitation behavior.","types":["measured quantity"],"aliases":["magnetizing current"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_1aef1ca08693e4ec5d8ff87ce66d9e63"},{"public_id":"co_4cfca04b64f8c830607df4e30dee65eb","status":"active","name":"sensor prototype","description":"A physical prototype of the current sensor used for experimental comparison.","types":["prototype"],"aliases":["prototype sensor"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_4cfca04b64f8c830607df4e30dee65eb"},{"public_id":"co_517c51e6f7adad6a4dae800ff36e1292","status":"active","name":"simulation model","description":"A computational model built to evaluate the sensor behavior under the target current condition.","types":["model"],"aliases":["simulated model"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_517c51e6f7adad6a4dae800ff36e1292"},{"public_id":"co_51eb2dbf7407ad90acd673d132d57ec4","status":"active","name":"theoretical analysis","description":"The analytical treatment used to derive and explain the sensor's behavior and errors.","types":["analysis"],"aliases":["theoretical investigation"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_51eb2dbf7407ad90acd673d132d57ec4"},{"public_id":"co_59b4e30efcca7cdb2448ac9f0f913303","status":"active","name":"secondary-side current","description":"The current on the secondary side of the sensor or transformer-like sensing system.","types":["measured quantity"],"aliases":["secondary current"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_59b4e30efcca7cdb2448ac9f0f913303"},{"public_id":"co_655e11ddabcd07d24289c999b38ee89e","status":"active","name":"mathematical model of current sensor","description":"A mathematical representation of the sensor behavior, including secondary-side current and excitation current.","types":["model"],"aliases":["sensor model"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_655e11ddabcd07d24289c999b38ee89e"},{"public_id":"co_8846a696d64f3a24110d4e992f9fa814","status":"active","name":"current sensor","description":"A sensor used to measure electric current in the studied leakage-current setting.","types":["sensor"],"aliases":["leakage current sensor"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_8846a696d64f3a24110d4e992f9fa814"},{"public_id":"co_ba8c63e28ab4ce57ec1e46573d3f5647","status":"active","name":"transformation process","description":"The sensor's current conversion behavior from input leakage current to output signal.","types":["process"],"aliases":["conversion process"],"contributors":[{"id":1,"public_id":"12632b8b5f","public_label":"Anonymous (12632b8b5f)","roles":["extraction"],"url":"https://sah.borca.ai/u/12632b8b5f"}],"url":"https://sah.borca.ai/concepts/co_ba8c63e28ab4ce57ec1e46573d3f5647"}],"external_ids":{"DOI":"10.1063/1.4975794","ArXiv":null,"PubMed":null,"PubMedCentral":null,"MAG":2587618232,"DBLP":null,"ACL":null},"open_access":{"is_open_access":true,"pdf_url":"https://aip.scitation.org/doi/pdf/10.1063/1.4975794","landing_url":"https://www.semanticscholar.org/paper/c2aaf021f9f0b20c55a637c8a964d1f8963ce57f","source":"semantic_scholar","pdf_url_source":"semantic_scholar_open_access_pdf","license":"CCBY","status":"GOLD","reason":null},"reference_availability":{"status":"available","references_indexed":true,"full_text_available":false,"full_text_source":null,"count_basis":"semantic_scholar_metadata","extraction_status":"not_applicable","reason":null},"source":{"provider":"episteme2","base_corpus":"semantic_scholar_dump","freshness_mode":"unknown","basis":["semantic_scholar_metadata","postgres_metadata"],"limits":["paper metadata is based on indexed upstream scholarly datasets","claims and concepts are available only for extracted papers","absence of claims or concepts means no extracted graph data is available in this response"],"status":"available","degraded":false,"degraded_reasons":[],"diagnostics":{"status":"available","degraded":false,"degraded_reasons":[],"metadata_status":"available","graph_status":"available","abstract_status":"available"},"source_flags":1},"paper_id":638174,"paper_uid":"a62d2a16-7c14-4d32-a1a6-e97f4c285e14","canonical_identity":{"paper_id":638174,"paper_uid":"a62d2a16-7c14-4d32-a1a6-e97f4c285e14","identity_status":"available","lookup_basis":"semantic_scholar_external_id","compatibility_path":"corpus_id"},"url":"https://sah.borca.ai/papers/99602955"}