Comparison of [18F]DCFPyL and [68Ga]Ga-PSMA-HBED-CC for PSMA-PET Imaging in Patients with Relapsed Prostate Cancer

M. Dietlein,C. Kobe,G. Kuhnert,Simone Stockter,T. Fischer,K. Schomäcker,M. Schmidt,Felix Dietlein,B. Zlatopolskiy,P. Krapf,R. Richarz,Stephan Neubauer,A. Drzezga,B. Neumaier

Published 2015 in Molecular Imaging and Biology

ABSTRACT

PurposeGallium-68 (Ga-68)-labeled tracers for imaging expression of the prostate-specific membrane antigen (PSMA) such as the [68Ga]Ga-PSMA-HBED-CC have already demonstrated high potential for the detection of recurrent prostate cancer. However, compared to Ga-68, a labeling with fluorine-18 (F-18) would offer advantages with respect to availability, production amount, and image resolution. [18F]DCFPyL is a promising F-18-labeled candidate for PSMA-positron emission tomography (PET) imaging that has been recently introduced. In the current study, we aimed to compare [68Ga]Ga-PSMA-HBED-CC and [18F]DCFPyL for clinical use in biochemically relapsed prostate cancer.ProceduresIn 14 selected patients with PSA relapse of prostate cancer, [18F]DCFPyL PET/X-ray computed tomography (CT) was performed in addition to [68Ga]Ga-PSMA-HBED-CC PET/CT. A systematic comparison was carried out between results obtained with both tracers with regard to the number of detected PSMA-positive lesions, the standardized uptake value (SUV)max and the lesion to background ratios.ResultsAll suspicious lesions identified by [68Ga]Ga-PSMA-HBED-CC were also detected with [18F]DCFPyL. In three patients, additional lesions were observed using [18F]DCFPyL PET/CT. The mean SUVmax in the concordant [18F]DCFPyL PSMA-positive lesions was significantly higher as compared to [68Ga]Ga-PSMA-HBED-CC (14.5 vs. 12.2, p = 0.028, n = 15). The mean tumor to background ratios (n = 15) were significantly higher for [18F]DCFPyL compared to [68Ga]Ga-PSMA-HBED-CC using kidney, spleen, or parotid as reference organs (p = 0.006, p = 0.002, p = 0.008), but no significant differences were found using the liver (p = 0.167) or the mediastinum (p = 0.363) as reference organs.Conclusion[18F]DCFPyL PET/CT provided a high image quality and visualized small prostate lesions with excellent sensitivity. [18F]DCFPyL represents a highly promising alternative to [68Ga]Ga-PSMA-HBED-CC for PSMA-PET/CT imaging in relapsed prostate cancer.

PUBLICATION RECORD

CITATION MAP

EXTRACTION MAP

CLAIMS

  • No claims are published for this paper.

CONCEPTS

  • No concepts are published for this paper.

REFERENCES

Showing 1-26 of 26 references · Page 1 of 1

CITED BY

Showing 1-100 of 355 citing papers · Page 1 of 4